![Norcold 121X series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/norcold/121x-series/121x-series_service-manual_1700922068.webp)
66
S
ection
8
Cooling System Diagnostic Flowchart
Do not bypass or modify the refrigerator
controls. Do not wire the heater directly.
Heaters are supplied power through a
fused circuit.
WARNING
Do not power ON the refrigerator if the
cooling system has a leak or is suspected
of having a leak.
WARNING
Begin
Any signs of leakage?
1
Check heat sources.
2
Signs of cooling system leakage:
• Yellow ammonia residue.
• Ammonia smell.
Installation/ventilation meet guidelines?
Replace cooling system
YES
YES
YES
Correct installation and ventilation
NO
3
Heat input device operating normally?
NO
Level refrigerator as specified in
Owner’s Manual.
Check as required:
AC heaters amp draw: 2.5 to 2.1 A per heater.
Burner: 7-slot., clean
Orifice: LP18, clean
Gas pressure: 10.5 to 11.5 in. w. c.
4
Leveled operation?
YES
NO
YES
Doors/gaskets okay?
5
Check condition of door gaskets
Align doors as required.
NO
Go to page 67
NO