48
S
ection
6
12 Volt DC Fans
Two 12 volt DC fans, illustrated in Figure 6-
5, installed on the cooling system foam plug
boost ventilation.
Fans are unidirectional and each fan draws
0.400 amps @ 12 volt DC. Fan resistance
through the fan motor circuit is approximately
1.8 ohms.
The fans are controlled by a thermostatic
switch. See
“Thermostatic Switch.”
Figure 6-5. —Fans and hardware.
Divider Heater
The divider heater is permanently “foamed”
between the freezer and fresh food
compartment divider. Powering on the
refrigerator automatically powers on the divider
heater. Power to the heater is continuously
supplied by the power board..
Figure 6-6. —Thermostatic switch for fans.
Thermostatic switch
The thermostatic switch is illustrated in Figure
6-6, In12 volt DC is fed through upper
terminal. The switch turns the fans on and
off. The fans come on when first condenser
fin temperature is approximately 130 degrees
Fahrenheit (54.4 degrees Celsius) and turn off
at approximately 115 degrees Fahrenheit (46
degrees Celsius).
Retaining screws
Fan
Fan
Bracket
Bracket
Spacer (2 per fan)
Screw, #8-32 x 1" (2 per bracket)
Condenser fin
Screw, #8-32 x 3/8" (2)
+12 VDC
in
+12 VDC
out
In roof vented installations it may be necessary
to remove the refrigerator from the enclosure
to test the thermostatic switch.
In sidewall installations the thermostatic switch
can be tested by removing the upper sidewall
vent..
IMPORTANT
Содержание 121X series
Страница 2: ...This page intentionally left blank...
Страница 10: ...8 Section 2 This page intentionally left blank...
Страница 96: ...94 Section 12 Section 12 Wiring Diagrams and Pictorials Figure 12 1 Wiring diagram...
Страница 97: ...Section 12 95 Figure 12 2 Wiring pictorial...
Страница 99: ...Section 12 97 This page intentionally left blank...