6
Function and adjustment
6.1
Logic of functions
S 01
01
02
03
04
05
06
DEAD MAN FuNCTION
The command
START
open, the
PARTIAL OPENING
closes. Motors stops immediatelly when the button
will be released.
RENvERSE
Each command START renverse
opens-closes
Automatic reclosing.
COLLECTIvE uSE
The
START
command can open or recharge the pause
time. Recloses automatically.
BI-STABLE FuNCTION
Each START has the following procedure:
open-stop-close-stop-open...
It recloses automatically.
BISTABLE FuNCTION
wITH AUTOMATIC RECLOSING
Each START has the following procedure:
open-stop-close-stop-open...
It recloses automatically.
S 02
S 04
S 19
S 09
01
RECLOSE wHEN THE CONTROL BOARD
wILL BE SwITCHED ON
It makes a complete open and
close cycle only in cas of lack of tension the gate was open.
01
SOFT-START
When the gate is opening, the speed increases
01
ACCESS CONTROL
When the photo-beams identify the passage, if
S19
is at
“0”
the pause time is 2 sec.
00
RENvERSE ON PASSAgE
Bring
S04
at
1
. The control unit renverse and closes.
INDuSTRIAL uSE
The Partial Opening became a closes contact and the
START follow the logic of
S01
-
S02
-
S03
-
S04