START-S11
Technical manual
-15-
5
Installation of the control unit
Connection to the
electric network
230 Vac
1
3
2
5.1
Connection of the TENSION
Neutral
Phase
230 Volt Single-phase alternate cur
-
rent. The control unit power supply
line must always be protected with
a magnetothermal switch or a pair
of 5A fuses.
A differential switch is recommended but not indi
-
spensable if one is already installed on the plant.
5.2
Connection of the MOTOR
6
7
4
Pay particular attention not to invert the OPEN and CLOSE
poles.
When in doubt as to the correct connection, if possible, ma
-
nually position the automation at the midpoint of its stroke. Be
ready to stop the system using the STOP control!
To be sure that the opening is really “opening”, try to block the
photocells: if the gate begins to close, the connection is incor
-
rect and the motor OPEN and CLOSE wires must be inverted.
8
9
10
11
5
MOTOR 2
Common
Open
Close
MOTOR 1
Common
Open
Close
4 5
Here is the connection of a 230Vac lamp with or
without flashing card.
To activate a function in
the pause time
,
see
S05
as shown:
S 05
LAMP IN PAUSE TIME
1 - Activated
0 - Deactivated
•
LAMP IN PAuSE TIME
5.3
Connection of the LAMP
4 5
26 27
with
flashing card
without
flashing card