12 13 14 15 16 17 18 19 20 21 22 23 24 25
START-S11
Technical manual
-20-
POWER SUPPLY OF
THE TRASMITTER
Receiver of the
photo-beam, NC contact
POWER SUPPLY
OF THE RECEIVER
The contact of the receiver
should be:
- Isolated
(isolated from tensions)
- Normally closed
If you use more photo-beams, the
connections should be serial.
5.17 Connection of a PHOTO-B with TEST
The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check
all connections before opening!
In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is
not working.
To activate the TEST put 1 in the PHOTO-B:
If you want to go back to the function WITHOUT TEST, connect the photo-cells like in the Par.
5.16
and bring
0
to the set up
S23
and
S06
(deactivate this function only in case other inputs are under TEST).
S 23
TEST
in
PHOTO-B
1 -
A
ctivated
0 - Deactivated
S 06
TEST
in the INPUT of the
SAfETiES
1 -
A
ctivated
0 - Deactivated
5.16 Connection of the PHOTO-B (opening and closing )
If the input PHOTO-STOP
is not used,
put S17 in 0
!
28 29 30 31 32
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY OF
THE TRASMITTER
Receiver of the
photo-beam, NC contact
POWER SUPPLY
OF THE RECEIVER