START-S11
Technical manual
-31-
Group functions
L
Set
up Description
Val. Accepted
Standard
Memo
L 01
Force level of MOTOR 1
da 1 a 100
70
L 02
Level of slow down MOTOR 1
da 1 a 100
10
L 03
Force level of MOTOR 2
(100 Off)
da 1 a 100
70
L 04
Level of slow down MOTOR 2
(100 Off)
da 1 a 100
10
L 05
Level of obstacle detection of MOT 1
(0 not activated)
da 1 a 100
30
L 06
Level of obstacle detection of MOT 2
(0 not activated)
da 1 a 100
30
L 07
Level of obstacle det. of MOT 1 slwoing down
(0 not activated)
da 1 a 100
0
L 08
Level of obstacle det. of MOT 2 slwoing down
(0 not activated)
da 1 a 100
0
Group functions
C
Imp. Description
Memo
C 01
TX learning for START command
Press P1
C 02
Tx learning for PARTIAL OPENING
Press P1
C 03
Cancellation of the memory code
Press P1
C 04
Cancellation of the code
Press P1
Group functions
P
Imp. Description
Val. Accepted Standard
Memo
P 01
Activation opening in time slots
0 Off - 1 On
0
P 02
Activation of the stop gates (from transmitter) in time slots
0 Off - 1 On
0
P 03
Insert the opeing time slot
Press P1
P 04
Insert of block time slots
Press P1
P 05
Cancellation of the opening time slots
Press P1
P 06
Cancellation of the block time slots
Press P1