START-S11
Technical manual
-7-
Neutral 230 Vac
1
230 Vac power supply 50Hz Neutral
Non usato
2
Non utilizzato
Phase 230 Vac
3
230Vac power supply 50Hz Phase
Lamp
4
Output for lamps (with flashing electronic card) or Courtesy light.
Maximum power of the lamp with 40.
5
M1 Com
6
Output for the connection of motor 2 COMMON pole
M1 Open
7
Output for the connection of motor 1 pole OPEN
M1 Close
8
Output for the connection motor 1 pole CLOSE
M2 Com
9
Output for the connection of motor 2 COMMON pole
M2 Open
10
Output for the connection of motor 2 pole OPEN
M2 Close
11
Output for the connection motor 2 pole CLOSE
CLS M2
12
Input close limit switch motor 2
OLS M2
13
Input Open limit switch motor 2
CLS M1
14
Input close limit switch motor 1
OLS M1
15
Input Open limit switch motor 1
Photo A
16
Input photo-beam A activated when closing (see par. 2.3)
START
17
Input bi-stable START
24Vac
18
Output 24Vac
24Vac / 12Vac
19
Output for electrical lock 12 Vac 50Hz 1A
12Vac elec. lock
20
Output for electrical lock 12 Vac 50Hz 1A
STOP
21
Input STOP
PEDESTRIAN
22
Input bi-stable command for partial opening
Photo B
23
Input photocell B activated when closing and opening
Common 1
-
24
Common for all input: services, safeties, coaxial cables
A
25
Input for antenna
LIGHT o Lamp.
26
Contact for LIGHT (for lamps without electronic card)
LIGHT o Lamp.
27
Contact for LIGHT (for lamps without electronic card)
PHOTOTEST
28
Isolated contact for interlock or test
PHOTOTEST
29
Isolated contact for interlock or test
12 Vac
30
Output 12 Vac
+ 24 Vdc
31
24 Vdc
- 24 Vdc / Comm.
32
Output - 24 Vdc /
Common, services and safeties
2.1
Electrical connections