23 24 25
17 18 19 20 21 22 23 24 25
17 18 19 20 21 22 23 24 25
START-S11
Technical manual
-18-
•
Button:
stop until a new command.
•
Switch:
it keep the automation closed until
a new command.
The connection of the safety devices is due to a
button or a normally closed contact. More devi
-
ces should be connected in parallel.
S 15
STOP
Input
1 - Activated
0 - Deactivated
5.10
STOP connection
If the input STOP
is not connected,
bring S15 into 0
!
If a electrical-magnetic block is available, bring
S26
into
1
and make as follow:
MOT
MOTOR
BRA
k
E
If you use this function for all time the motor is wor
-
king, the output for the electrical lock is powered,
this release the brake and the correct functon of
the motor.
S 26
Work function
RELEASE
of the BRAkE
1 - Activated
0 - Deactivated
If a wire is used as antenna, cut it to 17 cm for a
frequency of 433MHz and connect it to terminal.
5.11
Connection of the ANTENNA
5.12 Power of the
ACCESSORIES
17 18 19 20 21
30 31 32
+
-
Terminal board 18-19
Tension:
24 Vac
Terminal board 19-30
Tension: 12 Vac
Terminal board 31-32
Tension: 24 Vdc
5.13 C
onnection of the motor with
ELECTRO-MAgNETICAL BLOCk