12 13 14 15 16 17 18 19 20 21 22 23 24 25
START-S11
Technical manual
-19-
POWER SUPPLY OF
THE TRASMITTER
Receiver of the
photo-beam, NC contact
POWER SUPPLY
OF THE RECEIVER
The contact of the receiver
should be:
- Isolated
(isolated from tensions)
- Normally closed
If you use more photo-beams, the
connections should be serial.
5.15
Connection of the
PhOTO
A (activated when closing) with TEST
The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check
all connections before opening!
In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is
not working.
To activate the TEST put 1 in the PHOTO-A:
If you want to go back to the function WITHOUT TEST, connect the photo-cells like in the Par.
5.14
and bring
0
to the set up
S22
and
S06
(deactivate this function only in case other inputs are under TEST).
S 22
TEST
in
PHOTO-A
1 -
A
ctivated
0 - Deactivated
S 06
TEST
in the INPUT of the
SAfETiES
1 -
A
ctivated
0 - Deactivated
5.14
Connection of the PHOTO A 24 Vac (only when closing)
If the input PHOTO A
is not used,
put S16 in 0
!
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY OF
THE TRASMITTER
Receiver of the
photo-beam, NC contact
POWER SUPPLY
OF THE RECEIVER
28 29 30 31 32