Group functions
S
Set
up Description
Val. Accepted Standard Memo
S 01
Logic of function:
1 - Fast renverse
2 - Collective use
3 - Bistable function
4 - Bistable function with automatic reclosing
5 - Industrial use
6 - “Death man” function
from 1 to 6
1
S 02
Activation of SELF-CYCLE when the tension is coming again
0 Off - 1 On
0
S 03
Activation of COURTESY LIGHT on the lamp output
0 Off - 1 On
0
S 04
Activation of ACCESS CONTROL
0 Off - 1 On
0
S 05
Activation of LAMP IN PAUSE TIME
0 Off - 1 On
0
S 06
Activation of TEST in the inputs - OFF interblock
0 Off - 1 On
0
S 07
Activation of FIXED LIGHT
0 Off - 1 On
0
S 08
Activation of the ROLLING HCS function
0 Off - 1 On
0
S 09
Activation of the SOFT START
0 Off - 1 On
0
S 10
Activation of the MOTOR FUNCTION
0 Off - 1 On
0
S 11
Activation of input OLS1
0 Off - 1 On
1
S 12
Activation of input CLS1
0 Off - 1 On
1
S 13
Activation of input OLS2
0 Off - 1 On
1
S 14
Activation of input CLS2
0 Off - 1 On
1
S 15
Activation input STOP
0 Off - 1 On
1
S 16
Activation input PHOTO
0 Off - 1 On
1
S 17
Activation of the input PHOTO-STOP
0 Off - 1 On
1
S 18
RESET
of the standard programmed values
S 19
Activation of the RENVERSE by access control (S 04 = 1)
0 Off - 1 On
0
S 20
Logic of the OBSTACLE DETECTION:
1 - Works as LIMIT SWITCH
2 - Works as STOP
3 - Considered as STOP but before the motors renverse
from 1 to 3
1
S 21
Not used
S 22
Test in the input PHOTO when closing
0 Off - 1 On