Electrical System
62
Service Manual – Scrubtec R 253 - RA40
Troubleshooting
See the other chapters for previously provided instructions for other electrical system components
Trouble
Possible Causes
Remedy
The machine is not working
Batteries (BAT) flat or connections faulty
Charge the battery or clean the
connections
The batteries (BAT) are broken
Check the battery no-load voltage
The battery charger (CH) is broken
Replace
To restore the machine functioning,
disabling the on board battery
charger with sthe bridge connector
on the J4 connection placed on the
function electronic board (EB1)
The wiring harness is cut or pressed or short circuited
Repair
The ignition key (SW1) is broken
Replace
Note:
A damage to the battery charger or its connections can prevent the machine from
operating properly.