Recovery System
77
Service Manual – Scrubtec R 253 - RA40
Container and Vacuum System Motor Disassembly/Assembly (Continues)
10 Clean the inside of the containers from any dirt that has settled and check all gaskets (J) (Figure 10) for
wear; replace if necessary
Figure 10
J
J
J
Assembly
11 Check that all components are reassembled with the correct polarity and orientation
12 Assemble the components in the reverse order of disassembly
https://harrissupplyind.com - To Order Parts Call 608-268-8080