Electrical System
54
Service Manual – Scrubtec R 253 - RA40
Electrical System
Functional Description
The batteries (2 x 12V) are connected together in se-
ries by the cables
The battery charger (CH) is connected to the machine
by two connectors (C) (power connection to the batter-
ies) and C3 (4-way signal connection)
The grey and white cables (1 and 2 of connector C3)
are short circuited inside the battery charger (CH)
when this is not connected to the electrical mains If
this connection is not made, all machine functions are
disabled
If the optional battery charger has not been installed,
the relevant bridge must be used on connector C3
The “bridge” is installed at the function board J4 lo-
cation as shown in a photo below
J4 bridge connector
The green cable (terminal 4 of connector C3) is the
data cable between electronic board (EB1) and bat-
tery charger (CH)
This connection allows the battery charger charging
curve to the be set directly from the machine dash-
board and to view the operational state of the battery
charger during charging directly on the dashboard
display
Battery Charger
When the battery charger (CH) is connected to the
power supply, it provides a + 24V on J4 2: in this con-
dition the electronic board (EB1) disables all the con-
trol and functions except the battery status indicator
on the display electronic board (EB4)
Battery Charge State Display
Low voltage cut out
The Function electronic board shuts off electrical loads to protect the batteries from damage caused by over
discharging
The voltage threshold where loads are turned off depends on the battery type See table below
(Significant levels for machine operation)
INDICATION
TRANSITION THRESHOLD (VOLT)
CONSEQUENCE
WET
GEL
1
22V
22.2V
Little remaining run time, no block.
2
20.4V
21.6V
Brush OFF
3
19.4V
20.6V
Vacuum system OFF
4
18.4V
19.6V
Drive system OFF
https://harrissupplyind.com - To Order Parts Call 608-268-8080