Scrub System, Disc
80
Service Manual – Scrubtec R 253 - RA40
Wiring Diagram
DECK
ACTUATOR (M5)
J8.5
J2.2
J2.1
BR -
BR+
J8.10
DECK configurator return
Deck actuator power supply -/+
Deck actuator power /-
Brush motor -
Brush motor +
Power supply for DECK configurator
BRUSH
MOTOR (M1)
B+
B -
Electronic board power
Electronic board power supply -
FUNCTION ELECTRONIC
BOARD (EB1)
Figure 1
Brush Deck Actuator System
The brush deck actuator is a new generation actuator developed by SIR and ITALSEA and it is controlled
directly by the main board without electromechanical limit switches ITALSEA patented the system to control
the actuator. Basically the system uses deeply measurements of the current flow in the actuator to know its
position in real time
The actuator is mechanically proof of the end of stroke because of it reaches the end of stroke with limited volt-
age applied and so with a limited speed and force
The actuator moves and stops in 3 defined positions:
1)
RETRACTED: fully retracted end of stroke (deck lifted)
2)
WORK: intermediate position (deck on the floor, normal work condition)
3)
EXTRAPRESSURE: fully extended end of stroke (deck on the floor with extra pressure given pressing
the actuator integrated spring)
The actuator is powered at 50 % PWM (about 12Vdc) near the end of strokes or during the machine switch-on
reset feature, otherwise at 100 % PWM (24Vdc)
The machine switch-on reset feature moves the actuator from the position where it was the last time the ma-
chine was switched off to the retracted position
The quotes of the actuator strokes, with a tolerance of ±2mm are: Stroke RETRACTED-WORK = 3 3 in (85
mm), stroke RETRACTED-EXTRAPRESSURE (end to end) = 4 7 in (120 mm)
There are time out limits and amperometric limits related to the different phases of the movement as follow:
Movement from:
To:
PWM
AMP limit
Alarm if AMP limit is
reached
Timeout
Extrapressure
Work
100 % (=24Vdc)
4A per Time>1sec.
Yes
7.5 sec.
Work
Retracted –
0.4 in (10 mm)
100 %(=24Vdc)
4A per Time>1sec.
Yes
15 sec.
Retracted –
0.4 in (10 mm)
Retracted
50 %(=12Vdc)
2A per Time>1sec.
No (The electronic board
assumes the actuator reaches
the end of stroke)
Reset (switch on)
50 %(=12Vdc)
2A per Time>1sec.
No (The electronic board
assumes the actuator reaches
the end of stroke)
25 sec.
https://harrissupplyind.com - To Order Parts Call 608-268-8080