Alarm Log Screen (continues)
Improper uses of the batteries or battery charger are also recorded, as in the following table:
On-board Battery Charger Alarms
Alarm code
--------------------------
Description
Meaning
Condition
Effect
GB-N
-----------------------
CONTINUOUS
LOW BATTERY
VOLTAGE
Time of
continuous use
with discharged
batteries
“N” is the number of hours from key on to off
when the battery level is below 18.4V for WET
CELL (19.6 for AGM) batteries. This event is not
recorded if the usage time is below 10 minutes.
Incorrect use by customer. Risk of reduced
battery life.
GC
-----------------------
CHARGER
DISCONN
BEFORE END
CYCLE
Charging cycle
interrupted
before
completion
Disconnection of battery charger before stage IV
= battery symbol with 3 segments lit steadily.
Incorrect use by customer. Risk of reduced
battery life.
GD-N
-----------------------
CHARGING
TIME LESS
THAN 4 HOURS
Charging phase
duration
N = Number of hours from battery charger
connection to completion of PHASE II (red LED
on) if < 4
Incorrect use by customer. Risk of reduced
battery life.
Press the One-Touch button
to skip to the next Alarm logged
Press and keep pressed for 3 seconds the vacuum button
to reset the memory log