Recovery System
73
Service Manual – Scrubtec R 253 - RA40
Vacuum System Motor Amperage Test
Warning! This procedure must be performed by qualified personnel only.
1 Lift the recovery tank assembly and the driver’s seat
2 Apply the amp clamp (A) to a cable (B) near the vacuum unit (Figure 5)
3 Insert the operator key in its slot
4 Activate the vacuum by pressing the vacuum button
5 Check that the vacuum system motor amperage is between 13 and 17A at 24V
6 If the amperage is higher, remove the vacuum system motor (see the procedure in the Vacuum System
Motor Disassembly/Assembly paragraph), and check the condition of all its components to detect and
correct the abnormal amperage:
If the above-mentioned procedures do not produce the correct readings for the vacuum system motor
amperage, the motor must be replaced
Figure 5
B
A
https://harrissupplyind.com - To Order Parts Call 608-268-8080