Recovery System
69
Service Manual – Scrubtec R 253 - RA40
Recovery System
Functional Description
The recovery system removes the dirty water from
the floor and pipes it to a recovery tank. When the
machine is running, the dirty water on the floor is col
-
lected by the squeegee blades and collected through
the slots in the same, piped through the vacuum hose
and into the tank by the airflow created by vacuum
system motor (M2) The dirty water is piped into the
recovery tank, while the airflow continues to the vac
-
uum fan
A tank with a grid collects the largest debris going
through the recovery tank hose
The automatic float in the vacuum grid stops vacuum
system motor (M2) from collecting any liquids
The vacuum duct for connecting the vacuum grid to
the vacuum system motor (M2) is inside the recovery
tank cover
When the automatic float closes and shuts down the
vacuum system, the vacuum system motor noise will
increase and the floor will not be dried.
The gasket on the input of the vacuum system motor
allows full functionality of the system, while the filter
built-in the gasket prevents the passage of dirt and
debris
When the recovery tank is full it can be emptied
through the drain hose
Wiring Diagram
M2
B-
B+
FUNCTION ELECTRONIC
BOARD (EB1)
VA -
VA+
Vacuum system power supply -
Vacuum system power
VACUUM SYSTEM
MOTOR (M2)
Figure 1
https://harrissupplyind.com - To Order Parts Call 608-268-8080