Control System
27
Service Manual – Scrubtec R 253 - RA40
Super User Screen
The alarms activated during normal machine operation are stored and can be read in the corresponding log
(Alarm Log Screen)
Alarm Log Screen
The alarms log screen (F, Figure 6) function allows you to check any alarms stored on the machine
1 Turn the ignition key to “I” holding down both the horn button (A) together with the adjustment
percentage detergent button (B)
2 Press hold 1 second the reverse button (C) to switch to the screen menu (D)
3 Press the vacuum system button (E) to access the alarm log screen (F)
4 To return to the menu screen (D) repeatedly press the One-Touch button (G)
Figure 6
A
B
C
>1sec
E
G
F
D
Each alarm (See table of alarms in the Function Electronic Board Alarm Codes paragraph) is stored along with
the working hour (machine operating time counter) at which it occurred and all alarms are recorded in the
order in which they occurred, from the most recent to the oldest
The memory holds up to 20 alarm records, after which the oldest are overwritten when new alarms occur
https://harrissupplyind.com - To Order Parts Call 608-268-8080