Recovery System
75
Service Manual – Scrubtec R 253 - RA40
Container and Vacuum System Motor Disassembly/Assembly
Disassembly
1 Disassemble the vacuum system motor unit as shown in the previous paragraph
2 At the workbench, remove the terminals lock (A) (Figure 7) from the connector (B)
3 With a little screwdriver (C) move the splane lock (D) for disengaging the terminals from the connector
4 Remove the two terminals (E)
5 Carefully, slightly lift the splane lock (D), previously pressed, to restore it
Figure 7
D
C
A
D
B
E
https://harrissupplyind.com - To Order Parts Call 608-268-8080