Cleaning the Chemical Mixing System Detergent Tank
1 Drive the machine to the appointed disposal
area
2 Ensure that the machine is off and the operator
key (41) has been removed
3 Lift the recovery tank cover and check that it is
empty; if not, empty it using the drain hose
4 Close the recovery tank cover
5 Lift the recovery tank assembly and the driver’s
seat
6 Unscrew the plug (A, Figure 8) from the
detergent tank (B)
7 Remove the tank
8 Rinse and wash out the tank with clean water in
the appointed disposal area
9 Replace the detergent tank (B) as shown in the
figure, then refit the plug (A).
10 When the detergent tank has been drained, it
may be necessary to drain the Chemical Mixing
System too (see procedure in Draining the
Chemical Mixing System paragraph)