32
Installation and quick start commissioning guide - Commander ID300/302
5511 en - 2017.06 / a
QUICK START COMMISSIONING
Parameter
Function
Range
Default value
Menu 0
Adv.
menu
00.020
07.013
ADI2 Invert
0 or 1
0
00.021
07.030
ADI1 Offset
± 100.00 %
0.00 %
00.022
07.031
ADI2 Offset
± 100.00 %
0.00 %
00.023
-
Not used
00.024
07.020
ADIO3 Output Scaling
0.000 to 40.000
1.000
00.025
07.057
ADIO3 Output Control
0 to 16
16
00.026
08.022
DI2 Destination
0.000 to 30.999
• ID300:
06.038
• ID302: 0.000
00.027
07.019
ADIO3 Yellow LED Source
0.000 to 30.999
0.000
00.028
08.024
DI4 Destination
0.000 to 30.999
06.032
00.029
07.003
ADIO3 Output State
± 100.00 %
-
Common parameters
00.030
02.004
Ramp Mode Select
Fast, Standard,
Std boost, Fast boost
Fast
00.031
06.001
Stop Mode
Coast, Ramp, Ramp dc I, dc I
Timed dc I, Disable
Ramp
00.032
05.013
Dynamic V to F Select
0 or 1
1
00.033
06.009
Catch A Spinning Motor
Disable, Enable,
Fwd Only, Rev Only
Disable
00.034
01.010
Bipolar Reference Enable
0 or 1
0
00.035
08.081
DI1 Control
0 to 26
0
00.036
-
Not used
00.037
05.018
Maximum Switching
Frequency
2; 3; 4; 6; 8; 12; 16 kHz
3 kHz
00.038
05.012
Autotune
0
(1)
to 2
0
(1)
00.039
05.006
Motor Rated Frequency
0.00 to 550.00 Hz
50.00 Hz
00.040
05.011
Number of Motor Poles
0 to 16
0
(1)
00.041
05.014
Control Mode
Ur S, Ur, Fixed, Ur Auto,
Ur I, Square,
Fixed Tapered
Ur l
00.042
05.015
Low Frequency Voltage
Boost
0.0 to 25.0 %
3.0 %
00.043
11.025
Serial Baud Rate
600, 1200, 2400, 4800, 9600,
19200, 38400, 57600,
76800, 115200 bauds
115200 bauds
00.044
11.023
Serial Address
1 to 247
1
00.045
11.020
Reset Serial
communications
Off or On
Off
(1)
When the value is 0, the number of motor poles is automatically calculated by the drive.