Cleaning and maintenance reserved for the user must 

not be carried out by unsupervised children.

 

Before intervening on the system (maintenance, 

cleaning), always disconnect the product from the 

mains power supply and from any batteries.

 

The packing materials of the product must be disposed 

of in compliance with local regulations.

 

Inspect the system frequently, in particular the cables, 

springs and supports to detect any imbalances and 

signs of wear or damage. Do not use the product if it 

needs to be repaired or adjusted, because defective 

installation or incorrect balancing of the automation can 

lead to injuries.

PRODUCT DESCRIPTION AND INTENDED USE

2

 

PRODUCT DESCRIPTION AND INTENDED USE

MC824HR

 is an electronic control unit for automating swing gates. 

MC824HR

 is able to command electromechanical actuators of 

the type indicated in “

Table 4

”. It incorporates a system that verifies the force of the motors connected to it (amperometric function). 

This system allows for automatically detecting the limit switches, memorising the work time of each individual motor and detecting 

any obstacles during normal movement. These characteristics simplify the installation considerably, as the leaf offset and work 

times do not require any adjusting.

The control unit is programmed in advance for the most frequently used functions and incorporates a radio receiver for the remote controls. 

In addition, a straightforward procedure can be implemented to select more specific functions (see the “

PROGRAMMING

” chapter).

MC824HR

 is equipped with an SM-type connector for slot-in radio receivers (see the “

Connecting an SM-type radio receiver

“ 

paragraph) and an IBT4N-type connector which, through the IBT4N interface, can be used to connect BusT4 devices, such as the 

Oview programmer (see the “

Connecting the IBT4N interface

” paragraph).

The control unit is configured for being powered with PS324 back-up batteries which, in case of a power outage, function as an 

emergency power supply (see the “

Connecting the PS324 back-up battery

” paragraph). Moreover, the 

MC824HR

 is configured 

for being connected to a Solemyo solar power kit (see the “

Connecting the Solemyo system

” paragraph).

Any use of the product other than the intended use described is not allowed!

2.1  LIST OF CONTROL UNIT PARTS

The control unit consists of an electronic command and control board housed and protected in the box. “

Figure

 

1

” shows the main 

parts making up the board.

Close

Open

SbS

Stop

OGI

ENC

ENC

ELS

Flash

Bluebus

1 2 3 4 5 6 7 8 9 10 11 12

Close

Open

SbS

Stop

Bluebus

8 9 10 11 12

J

K

M N O Q R

B
A

C

D

E

F

G

H

I

P1

P2
P3

L1

U
V

L8

..

S
T

L9

L10

L11

L12

L13

M

M
M

M

X

W

Nice S.p.A.

Via Callalta, 131046 Oderzo

TV Italy

1

A

 

24 V~ power supply connector

B

 

M2  motor  terminal  (starts  first  during  the  opening 

phase)

C

 

M1  motor  terminal  (starts  first  during  the  closing 

phase)

D

 

Warning light terminal

E

 

Electric lock output terminal

F

 

OGI (open gate indicator) output terminal

G

 

Motor M2 encoder input terminal

H

 

Motor M1 encoder input terminal

I

 

“SM” connector for radio receiver

J

 

Terminals for radio antenna

K

 

Motor type selectors

M

 

Bluebus input terminal

N

 

Stop input terminal

O

 

SbS (Step-by-Step) input terminal

Q

 

Open input terminal

R

 

Close input terminal

P1..P3

 

Control unit programming buttons

L1..L8

 

Programming LED

L9..L13

  Input LEDs

S

 

Connector for IBT4N

T

 

Service fuse (2 A, type F)

U

 

Connector for PS324 back-up battery / Solemyo solar 

power kit

V

 

Motor fuses (15 A)

W

 

Mains power supply (L-Live; N-Neutral)

X

 

Cable clamp

Содержание MC824HR

Страница 1: ...Nice MC824HR Control unit EN Instructions and warnings for installation and use...

Страница 2: ...handle the product with care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these actions can dam...

Страница 3: ...paragraph and an IBT4N type connector which through the IBT4N interface can be used to connect BusT4 devices such as the Oview programmer see the Connecting the IBT4N interface paragraph The control u...

Страница 4: ...form the successive operations thus preventing the two leaves from striking the opening and closing mechanical stops m IMPORTANT if the Stand by all function is active the manual movement of the leave...

Страница 5: ...ectronic circuits 3 5 INSTALLING THE CONTROL UNIT a Secure the control unit to an unmovable vertical flat surface adequately protected against possible impacts The lower part of the control unit must...

Страница 6: ...y III overvoltage conditions in accordance with the installation instructions If necessary this device guarantees quick and safe disconnection from the mains power and therefore must be positioned in...

Страница 7: ...ed resistor output such as sensitive edges can be connected to this input Each device connected to this input will be individually recognised by the control unit during the learning phase see Learning...

Страница 8: ...opening stops and restarts when the photocell disengages PHOTOCELL ADDRESSES Photocell Position of the jumpers FOTO 2 PHOTO 2 Internal photocell triggered during the opening phase stops and reverses t...

Страница 9: ...m closing This procedure can be carried out in three different ways automatic manual and mixed In automatic mode the control unit learns the mechanical stops calculates the most appropriate gate leaf...

Страница 10: ...on to stop the learning phase At this point invert the control wires external positions with respect to the terminal on the motor that executed the opening manoeuvre and repeat the self learning proce...

Страница 11: ...button is released LED L7 will start flashing 9 LED L7 flashes position 1 of M1 to command and move motor 1 to position 1 Figure 14 press and hold the f or h button Once the position is reached relea...

Страница 12: ...y whether the leaves can be opened and closed with a force below 390 N 3 lock the motors as described in the respective instruction manual 4 using the control devices transmitter control button key se...

Страница 13: ...2 release the g button when LED L1 starts flashing 3 press the f or h button to move the flashing LED to the LED associated with the function to be modified 4 press the g button to change the status...

Страница 14: ...TABLE PARAMETERS All the Level 2 parameters are factory set as highlighted in GREY in Table 7 and can be modified at any time The parameters can be set to a scale of 1 to 8 The check the value corresp...

Страница 15: ...executed if the sent command remains if the command is interrupted the manoeuvre stops L8 Semi automatic opening hold to run closing L3 Motor speed L1 Very slow Adjusts the motor speed during normal t...

Страница 16: ...roceed with point 2 2 within 3 seconds press the control again and hold it down 3 after roughly 2 seconds the gate will complete the requested manoeuvre in hold to run mode in other words it will cont...

Страница 17: ...stance Verify the cause and increase the motor force if necessary 4 short flashes 1 second pause 4 short flashes Intervention of the STOP input At the start of the manoeuvre or during the movement its...

Страница 18: ...blown verify the cause and replace it with one having the same characteristics Green LED always on Serious anomaly There is a serious problem try disconnecting the power supply to the control unit an...

Страница 19: ...ton to shift flashing of the LED to L8 Anomaly list parameter 4 keep the g button pressed down it must be kept pressed throughout phases 5 and 6 5 wait roughly 3 seconds after which LED L1 correspondi...

Страница 20: ...mation Unlock or only from Oview the following commands Unlock and close and Unlock and open 12 Lock automation Triggers the stoppage of the manoeuvre and locks the automation the control unit will no...

Страница 21: ...CT MAINTENANCE Being an electronic part the control unit does not require any special maintenance Nonetheless the system should be regularly checked to ensure that it works efficiently at least every...

Страница 22: ...us triggers the STOP command SbS input for normally open contacts the closing of the contact triggers the Step by Step command OPEN input for normally open contacts the closing of the contact triggers...

Страница 23: ...ding to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to machinery and amending...

Страница 24: ...24 ENGLISH NOTES...

Страница 25: ...y but contact your trusted installer l Do not modify the system or the programming and adjustment parameters of the control unit your installer is exclusively responsible for these operations Failure...

Страница 26: ...26 ENGLISH NOTES...

Страница 27: ...ENGLISH 27 NOTES...

Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0133A01EN_15 01 2019...

Отзывы: