TECHNICAL SPECIFICATIONS

11

 

11 

TECHNICAL SPECIFICATIONS

All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A. 

reserves the right to apply modifications to the product at any time when deemed necessary, without altering 

its functions and intended use.

Table 14

TECHNICAL SPECIFICATIONS

Description

Technical specification

Mains power supply

MC824HR control unit: 230 V

a

 ± 10% 50–60 Hz

MC824HR/V1 control unit: 120 V

a

 ± 10% 50–60 Hz

Nominal power absorbed by the 

mains grid

200 W

Power draw of the control unit battery 

connector in “Stand-by all” mode

(including a receiver with SM-type 

connector)

below 100 mW

Warning light output [Note 1]

1 ELDC warning light

Electric lock output [Note 1]

1 x 12 V

a

 max 15 VA electric lock

Gate open indicator output [Note 1]

For 1 x 24 V maximum 4 W lamp (the output voltage may vary between –30% and +50% and 

can also control small relays)

BLUEBUS output

1 output with maximum load of 15 Bluebus units (maximum 6 pairs of MOFB or MOFOB 

phot 2 pairs of MOFB or MOFOB photocells addressed as opening d 

maximum 4 MOMB or MOTB control devices

STOP input

for normally closed or normally open contacts or for 8.2 kΩ fixed resistor contacts with self-

learning (any variation from the memorised status triggers the “STOP” command)

SbS input

for normally open contacts (the closing of the contact triggers the “Step-by-Step” command)

OPEN input

for normally open contacts (the closing of the contact triggers the “OPEN” command)

CLOSE input

for normally open contacts (the closing of the contact causes the “CLOSE” command)

Radio connector

SM connector for SMXI, OXI and OXFIM receivers

Radio ANTENNA input

50 Ω for RG58-type cable or similar

Programmable functions

8 ON-OFF and 8 adjustable functions

Self-learning functions

Self-learning of the devices connected to the BlueBus output; self-learning of the type of 

device connected to the “STOP” terminal (NO, NC contact or 8.2 kΩ fixed resistor); self-

learning of the gate leaf path and automatic calculation of the slowdown and partial opening 

points (which vary depending on the type of installation)

Operating temperature

-20°C ... +55°C

Use in highly acid, saline or 

potentially explosive atmosphere

NO

Protection rating

IP 54 with container intact

Dimensions (mm)

310 x 232 x H 122

Weight (kg)

4,1

Note 1

  The “Warning light”, “Electric lock” and “Gate open indicator” outputs can be programmed with other functions (see “

Table 

6

” in the 

Level 1 programming (ON-OFF)

” paragraph) or through the Oview programmer (refer to the “

Connecting the 

IBT4N interface

” paragraph). The electrical characteristics of the output adapt to the programmed functions: warning light 

(12 V

c

, max 21 W lamp) - electric lock (12 V

a

, max 15 VA) - other outputs (all types: 1 x 24 V lamp or relay

c

, –30% to 

+50%, 4 Wmax).

Содержание MC824HR

Страница 1: ...Nice MC824HR Control unit EN Instructions and warnings for installation and use...

Страница 2: ...handle the product with care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these actions can dam...

Страница 3: ...paragraph and an IBT4N type connector which through the IBT4N interface can be used to connect BusT4 devices such as the Oview programmer see the Connecting the IBT4N interface paragraph The control u...

Страница 4: ...form the successive operations thus preventing the two leaves from striking the opening and closing mechanical stops m IMPORTANT if the Stand by all function is active the manual movement of the leave...

Страница 5: ...ectronic circuits 3 5 INSTALLING THE CONTROL UNIT a Secure the control unit to an unmovable vertical flat surface adequately protected against possible impacts The lower part of the control unit must...

Страница 6: ...y III overvoltage conditions in accordance with the installation instructions If necessary this device guarantees quick and safe disconnection from the mains power and therefore must be positioned in...

Страница 7: ...ed resistor output such as sensitive edges can be connected to this input Each device connected to this input will be individually recognised by the control unit during the learning phase see Learning...

Страница 8: ...opening stops and restarts when the photocell disengages PHOTOCELL ADDRESSES Photocell Position of the jumpers FOTO 2 PHOTO 2 Internal photocell triggered during the opening phase stops and reverses t...

Страница 9: ...m closing This procedure can be carried out in three different ways automatic manual and mixed In automatic mode the control unit learns the mechanical stops calculates the most appropriate gate leaf...

Страница 10: ...on to stop the learning phase At this point invert the control wires external positions with respect to the terminal on the motor that executed the opening manoeuvre and repeat the self learning proce...

Страница 11: ...button is released LED L7 will start flashing 9 LED L7 flashes position 1 of M1 to command and move motor 1 to position 1 Figure 14 press and hold the f or h button Once the position is reached relea...

Страница 12: ...y whether the leaves can be opened and closed with a force below 390 N 3 lock the motors as described in the respective instruction manual 4 using the control devices transmitter control button key se...

Страница 13: ...2 release the g button when LED L1 starts flashing 3 press the f or h button to move the flashing LED to the LED associated with the function to be modified 4 press the g button to change the status...

Страница 14: ...TABLE PARAMETERS All the Level 2 parameters are factory set as highlighted in GREY in Table 7 and can be modified at any time The parameters can be set to a scale of 1 to 8 The check the value corresp...

Страница 15: ...executed if the sent command remains if the command is interrupted the manoeuvre stops L8 Semi automatic opening hold to run closing L3 Motor speed L1 Very slow Adjusts the motor speed during normal t...

Страница 16: ...roceed with point 2 2 within 3 seconds press the control again and hold it down 3 after roughly 2 seconds the gate will complete the requested manoeuvre in hold to run mode in other words it will cont...

Страница 17: ...stance Verify the cause and increase the motor force if necessary 4 short flashes 1 second pause 4 short flashes Intervention of the STOP input At the start of the manoeuvre or during the movement its...

Страница 18: ...blown verify the cause and replace it with one having the same characteristics Green LED always on Serious anomaly There is a serious problem try disconnecting the power supply to the control unit an...

Страница 19: ...ton to shift flashing of the LED to L8 Anomaly list parameter 4 keep the g button pressed down it must be kept pressed throughout phases 5 and 6 5 wait roughly 3 seconds after which LED L1 correspondi...

Страница 20: ...mation Unlock or only from Oview the following commands Unlock and close and Unlock and open 12 Lock automation Triggers the stoppage of the manoeuvre and locks the automation the control unit will no...

Страница 21: ...CT MAINTENANCE Being an electronic part the control unit does not require any special maintenance Nonetheless the system should be regularly checked to ensure that it works efficiently at least every...

Страница 22: ...us triggers the STOP command SbS input for normally open contacts the closing of the contact triggers the Step by Step command OPEN input for normally open contacts the closing of the contact triggers...

Страница 23: ...ding to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to machinery and amending...

Страница 24: ...24 ENGLISH NOTES...

Страница 25: ...y but contact your trusted installer l Do not modify the system or the programming and adjustment parameters of the control unit your installer is exclusively responsible for these operations Failure...

Страница 26: ...26 ENGLISH NOTES...

Страница 27: ...ENGLISH 27 NOTES...

Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0133A01EN_15 01 2019...

Отзывы: