LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry
LED
Parameter
LED
(level)
Set value
Description
L2
Step-by-Step
function
L1
Open - Stop - Close - Stop
Controls the sequence of
commands associated with the
“SbS”, “Open” and “Close” inputs
or the radio control.
Note:
setting
L4
,
L5
,
L7
and
L8
, the
behaviour of the “Open” and
“Close” commands also changes.
L2
Open - Stop - Close - Open
L3
Open - Close - Open - Close
L4
CONDOMINIUM
During the opening manoeuvre
, the “Step-by-Step” and
“Open” commands do not cause any effect; instead the
“Close” command causes the movement to reverse, namely
the closing of the gate leaves.
During the closing manoeuvre
, the “Step-by-Step” and
“Open” commands cause a reversal of the movement, namely
the opening of the gate leaves; instead the “Close” command
does not cause any effect.
L5
CONDOMINIUM 2
During the opening manoeuvre
, the “Step-by-Step” and
“Open” commands do not cause any effect; instead the
“Close” command causes the movement to reverse, namely
the closing of the gate leaves. If the sent command remains
for more than 2 seconds, a “Stop” command is executed.
During the closing manoeuvre
, the “Step-by-Step” and
“Open” commands cause a reversal of the movement, namely
the opening of the gate leaves; instead the “Close” command
does not cause any effect. If the sent command remains for
more than 2 seconds, a “Stop” command is executed.
L6
STEP-BY-STEP 2 (less than 2 seconds causes partial
opening)
L7
HOLD-TO-RUN
The manoeuvre is only executed if the sent command
remains; if the command is interrupted, the manoeuvre stops.
L8
“Semi-automatic” opening, “hold-to-run” closing.
L3
Motor speed
L1
Very slow
Adjusts the motor speed during
normal travel.
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely fast
L7
Opens “Fast”; closes “Slow”
L8
Opens “Extremely fast”; closes “Medium”
L4
Motor
discharge after
closing
L1
No discharge
Adjusts the duration of the “brief
reversal” of both motors, after
completing the closing manoeuvre,
to reduce the residual final thrust.
L2
Level 1 - Minimum discharge (roughly 100 ms)
L3
Level 2 - ...
L4
Level 3 - ...
L5
Level 4 - ...
L6
Level 5 - ...
L7
Level 6 - ...
L8
Level 7 - Maximum discharge (roughly 800 ms)
L5
Motor force
L1
Level 1 - Minimum force
Adjusts the force of both motors.
L2
Level 2 - ...
L3
Level 3 - ...
L4
Level 4 - ...
L5
Level 5 - ...
L6
Level 6 - ...
L7
Level 7 - ...
L8
Level 8 - Maximum force
L6
Pedestrian or
partial opening
L1
Pedestrian 1 (the M2 gate leaf opens to 1/4 of the full length)
Adjusts the type of opening
associated with the “partial opening
1” command.
In levels L5, L6, L7 and L8,
“minimum” opening refers to the
smallest opening between M1
and M2; for example, if M1 opens
to 90° and M2 opens to 110°, the
minimum opening is 90°.
L2
Pedestrian 2 (the M2 gate leaf opens to 1/2 of the full length)
L3
Pedestrian 3 (the M2 gate leaf opens to 3/4 of the full length)
L4
Pedestrian 4 (full opening of gate leaf 2)
L5
Partial 1 (the two gate leaves open to 1/4 of the “minimum”
opening level)
L6
Partial 2 (the two gate leaves open to 1/2 of the “minimum”
opening level)
L7
Partial 3 (the two gate leaves open to 3/4 of the “minimum”
opening level)
L8
Partial 4 (the two gate leaves open to the “minimum” opening
level)