ENGLISH –
5
TECHNICAL SPECIFICATIONS OF ELECTRICAL CABLES
Identification
no.
Cable characteristics
f
MOTOR POWER SUPPLY cable
1 cable 3 x 1.5 mm
2
Maximum length 10 m [
note 4
]
g
ELECTRIC LOCK CONNECTION cable
1 cable 2 x 1 mm
2
Maximum length 10 m
h
ENCODER CONNECTION cable
1 cable 2 x 1 mm
2
Maximum length 10 m [
note 4
]
Note 1
If the power supply cable is longer than 30 m, a cable
with larger cross-sectional area (3 x 2.5 mm
2
) must be
used and a safety earthing system must be installed
near the automation.
Note 2
If the BlueBus cable is longer than 20 m, up to maximum
40 m, a cable with larger gauge (2 x 1 mm
2
) must be
used.
Note 3
These two cables can be replaced by a single 4 x 0.5
mm
2
cable.
Note 4
These cables can be replaced by a single 5 x 1.5 mm
2
cable.
a
The cables used must be suited to the type of
environment of the installation site.
a
When laying the ducting for routing the electrical
cables and for the cable entry point into the
control unit housing, check that there are no water
deposits in the junction wells nor condensate in the
connection ducts, as water and damp conditions
could damage the product’s electronic circuits.
3.5 INSTALLING THE CONTROL UNIT
a
Secure the control unit to an unmovable, vertical,
flat surface adequately protected against possible
impacts. The lower part of the control unit must be
at least 40 cm above the ground.
l
The control unit is also suitable for being installed
outdoors, as it is supplied in a container that, if
adequately installed, guarantees an IP54 protection
rating.
To secure the control unit (“
Figure
” and “
Figure
”):
1.
loosen the screws (
A
) and remove the cover (
B
) of the
control unit
2.
identify the pre-cut holes (
C
) located along the lower
side of the box and perforate the ones used to pass the
electrical cables
l
The side cable entry (D) can only be used if the
control unit is installed indoors, in a protected
environment.
B
D
A
C
5
3.
drill the wall (
E
) by observing the measurements shown in
the figure and arrange suitable wall plugs (not supplied)
4.
position the box (
F
) and fasten it with the screws (
G
) (not
supplied)
5.
arrange cable glands for passing the connecting cables
6.
make the electrical connections by operating as described
l
To install any other devices used on the automated
system, refer to the respective instruction manuals.
7.
after making the electrical connections, put the cover (
B
)
back on and tighten the screws (
A
).
205 mm
237 mm
E
G
F
6
Содержание MC824HR
Страница 1: ...Nice MC824HR Control unit EN Instructions and warnings for installation and use...
Страница 24: ...24 ENGLISH NOTES...
Страница 26: ...26 ENGLISH NOTES...
Страница 27: ...ENGLISH 27 NOTES...
Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0133A01EN_15 01 2019...