REMOTE CONTROL
243
<NR3>
floating point with exponent
4.5e-1, 8.25e+1
<NRf>
any of NR1, 2, 3
1, 1.5, 4.5e-1
[MIN]
(Optional
parameter)
For commands, this will set the setting to the
lowest value. This parameter can be used in
place of any numerical parameter where
indicated.
For queries, it will return the lowest possible
value allowed for the particular setting.
[MAX]
(Optional
parameter)
For commands, this will set the setting to the
highest value. This parameter can be used in
place of any numerical parameter where
indicated.
For queries, it will return the highest possible
value allowed for the particular setting.
DEF
For commands, this will set the setting to the
default value. This parameter can be used in
place of any numerical parameter where
indicated.
For queries, it will return the default value
allowed for the particular setting.
Automatic
parameter
range
selection
The DM2571 automatically sets the command parameter to the
next available value.
Example
conf:volt:dc 3
This will set the measurement item to DC
Voltage and the range to 10V. There is no
3V range so the DMM selects the next
available range, 10V.
Message
Terminator
(EOL)
Remote
Command
Marks the end of a command line. The
following messages are in accordance with
IEEE488.2 standard.
LF, CR, CR+LF,
LF+CR
The most common
EOL character is
CR+LF
Message
Separator
EOL or ;
(semicolon)
Command Separator
Содержание DM2571
Страница 1: ...NF Corporation DIGITAL MULTIMETER DM2571 USER MANUAL ...
Страница 2: ......
Страница 3: ...DA00078064 002 DIGITAL MULTIMETER DM2571 USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 76: ...DM2571 User Manual 72 ...
Страница 137: ...SYSTEM FIRMWARE 133 SYSTEM FIRMWARE View System Info 134 Firmware Update 135 ...
Страница 176: ...DM2571 User Manual 172 ...
Страница 177: ...SCREENSHOT LOG 173 SCREENSHOT LOG Capture 174 Save Reading 177 ...
Страница 185: ...DISPLAY SETTING 181 DISPLAY SETTING Digit 182 Display 184 Number 184 Bar Meter 185 Trend Chart 189 Histogram 198 ...
Страница 244: ...DM2571 User Manual 240 ...
Страница 261: ...REMOTE CONTROL 257 SAV 328 SRE 328 SRE 328 STB 328 TRG 329 WAI 329 ...
Страница 334: ...DM2571 User Manual 330 Status system The diagram below is a description of the status system ...
Страница 348: ...DM2571 User Manual 344 DCV Ratio 5 Accuracy Specification DC Input accuracy DC Reference accuracy ...
Страница 360: ...DM2571 User Manual 356 Dimensions All dimensions are shown in millimeters Optional GPIB card is installed ...
Страница 362: ......
Страница 363: ......
Страница 364: ......
Страница 366: ......
Страница 368: ......
Страница 369: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama223 8508JAPAN ...