DM2571 User Manual
264
CALCulate:LIMit:DATA?
Returns the low / high fail count of the compare function.
Return Parameter: <NR1>
CALCulate:LIMit:LOWer[:DATA]
Sets the lower limit value of the compare function.
Parameter: <NRf> (-1.2E+08 to 1.2E+08) | MIN | MAX | DEF
Example:
CALC:LIM:LOW:DATA -1.0
Sets the lower limit to -1.0
CALCulate:LIMit:LOWer[:DATA]?
Returns the lower limit value of the compare function.
Return parameter: <NRf>
CALCulate:LIMit:UPPer[:DATA]
Sets the upper limit value of the compare function.
Parameter: <NRf> (-1.2E+08 to 1.2E+08) | MIN | MAX | DEF
Example:
CALC:LIM:UPP:DATA 1.0
Sets the upper limit to 1.0
CALCulate:LIMit:UPPer[:DATA]?
Returns the upper limit value of the compare function.
Return parameter: <NRf>
CALCulate:LIMit[:STATe]
Sets the status on/off for the compare function.
Parameter: 0 | 1 | ON | OFF
Example:
CALC:LIM:STAT 1
Sets the compare function to on.
CALCulate:LIMit[:STATe]?
Returns the status of the compare function.
CALCulate:DB:REFerence
Sets the reference value for the dB function.
Parameter: <NRf> | MIN | MAX | DEF
RefMethod:
Voltage: (-1200 to 1200 V)
dBm: (-200.0 to 200 dBm)
Example: CALC:DB:REF MAX
Sets the reference value for dB measurements to the maximum allowed.
CALCulate:DB:REFerence?
Returns the reference value from the dB function.
Return parameter: <NRf>
Содержание DM2571
Страница 1: ...NF Corporation DIGITAL MULTIMETER DM2571 USER MANUAL ...
Страница 2: ......
Страница 3: ...DA00078064 002 DIGITAL MULTIMETER DM2571 USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 76: ...DM2571 User Manual 72 ...
Страница 137: ...SYSTEM FIRMWARE 133 SYSTEM FIRMWARE View System Info 134 Firmware Update 135 ...
Страница 176: ...DM2571 User Manual 172 ...
Страница 177: ...SCREENSHOT LOG 173 SCREENSHOT LOG Capture 174 Save Reading 177 ...
Страница 185: ...DISPLAY SETTING 181 DISPLAY SETTING Digit 182 Display 184 Number 184 Bar Meter 185 Trend Chart 189 Histogram 198 ...
Страница 244: ...DM2571 User Manual 240 ...
Страница 261: ...REMOTE CONTROL 257 SAV 328 SRE 328 SRE 328 STB 328 TRG 329 WAI 329 ...
Страница 334: ...DM2571 User Manual 330 Status system The diagram below is a description of the status system ...
Страница 348: ...DM2571 User Manual 344 DCV Ratio 5 Accuracy Specification DC Input accuracy DC Reference accuracy ...
Страница 360: ...DM2571 User Manual 356 Dimensions All dimensions are shown in millimeters Optional GPIB card is installed ...
Страница 362: ......
Страница 363: ......
Страница 364: ......
Страница 366: ......
Страница 368: ......
Страница 369: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama223 8508JAPAN ...