3)
Wash Activation Signal #2:
Wiring for the second wash activation signal
can be brought in through one of the conduit connectors on the control box,
and connected to Terminal #7 (hot) and Terminal #8 (common) on the
block in the lower left corner. This signal runs through activation signal
relay #3. This activation should be the same or a higher flow demand than
#1.
4)
Wash Activation Signal #3:
Wiring from the second wash activation
signal can be brought in through one of the conduit connectors on the
control box, and connected to Terminal #9 (hot) and Terminal #10
(common) on the block in the lower left corner. This signal runs through
activation signal relay #4. This activation should be the highest flow
demand.
c)
Wall Mounted Ozone System:
Some large models require the oxygen
concentrator / ozone generator system to be wall mounted. In these cases, the
power and control wiring for the wall mount system must be field wired into the
main reclaim control box. A conduit connector with numbered wires out of the
main control box must be wired into the junction box on the wall mount system.
The numbered wires correspond to the numbered terminals in the junction box.