System Installation
PurWater systems are designed for easy installation. However, if you should have
any questions, please contact us at (916) 978-9990 or (800) 882-8854 in
Sacramento, CA. Office hours are 7AM to 5 PM, Pacific Standard Time, Mon-Fri.
I. PW 100/200/300-5M Series Reclaim Systems,
including:
a) Model PW100-5MAS (3HP, 30 GPM, Air Sparger)
b) Model PW100-5MB (3HP, 30 GPM, Enzyme Feed System and Air
Sparger)
c) Model PW100-5M12O (3HP, 30 GPM, 12 Gram Ozone)
d) Model PW200-5MAS (5HP, 60 GPM, Air Sparger)
e) Model PW200-5MB (5HP, 60 GPM, Enzyme Feed System and Air
Sparger)
f) Model PW200-5M12O (5HP , 60 GPM, 12 Gram Ozone)
g) Model PW200-5M24O (5HP , 60 GPM, 24 Gram Ozone)
h) Model PW300-5MAS (5HP, 90 GPM, Air Sparger)
i) Model PW300-5MB (5HP, 90 GPM, Enzyme Feed System and Air
Sparger)
j) Model PW300-5M12O (5HP , 90 GPM, 12 Gram Ozone)
k) Model PW300-5M24O (5HP , 90 GPM, 24 Gram Ozone)
Frame:
The system is to be installed in a dry / clean / temperature controlled / covered
area. It is not designed to be in the wash bay or outdoors. The frame requires a
floor space of 48” wide by 16” deep, with a height of 75” (86” for ozone units). We
recommend a minimum clearance of 18” along the sides, front and top of all frames
to allow for routine maintenance and inspection. The floor frame should be placed
with its back along a wall and should be secured to the wall to prevent movement
of the frame. Some models may also have a wall mount frame for the ozone
generation system. This wall mount frame needs to set in close proximity of the
floor frame to allow both electrical and piping connections. The area should be free
of excessive moisture which can cause extreme corrosion or electrical failure.
Piping:
Fittings on these systems have some threaded connections which can come loose
during shipment. There are two unions used on the motorized ball valve on the inlet
piping, on the cyclone overflow piping, on the check valve on the recirculation line,
and on the Mazzei eductor (on ozone units only) on the recirculation line. There is
also a union on the cyclone underflow. Re-tighten these union connections and any
other threaded connections prior to introducing water into the system. We
recommend using Schedule 80 PVC for all connections to the reclaim unit. Rubber
hose is acceptable on all lines except the Suction Line (needs reinforced suction
hose) and the Recirculation Line on ozone systems (rubber is not compatible with
ozone).