1)
The Catch Basin is typically located in the bay and
is part of the trench used to collect water from the
wash that goes to the Reclaim Tanks.
2)
The Catch Basin will collect heavy, large solids
(rocks) and floating materials (plastic bags &
bottles), keeping these items out of the Reclaim
Tanks.
3)
The outlet of the Catch Basin must have an elbow
below the water level that will prevent floating
trash from entering the Reclaim Tanks. This elbow
also prevents ozone gas in the Reclaim Tanks from
moving up the inlet pipe and into the bay.
4)
The separated solids (underflow) line from the
PurWater Reclaim Unit should be piped into the
Catch Basin. The drain line between the PurWater
Reclaim Unit and the Catch Basin should have a
minimal number of elbows to prevent plugging and
be large enough (2” to 3”) to allow for cleaning.