Page 40/ 191
6.3 Power
This unit has 1x 100 TX PoE port, receiving 802.3af compliant PoE @48V. The total power budget
is 3.6 Watts. This device fully relies on the Ethernet PoE supplied from the Core Module without
which it will not operate.
6.4 Connections
The BCU allows for up to 3x NMEA (IEC61162-2) serial ports to be connected and recorded to
the VDRs Core Module. These will typically be used i.e. for GPS, AIS, etc. Data rates supplied
are up to 38k4 for all ports.
The BCU provides an Auxiliary CAUTION relay with a contact rating of 28V DC, 200mA max.
During correct functioning of the VDR, the relay contacts are in the NO position. When a CAUTION
condition occurs or the VDR loses its power, the NC position is valid. (NC=normally closed,
CO=COMMON contact, NO=normally open).
NMEA connections to the BCU are to be connected as follows.
Connector
Data rate
N1
NMEA channel 1 A
4k8 ~ 38k4
N2
NMEA channel 1 B
N3
NMEA channel 1 Common
N4
NMEA channel 2 A
N5
NMEA channel 2 B
N6
NMEA channel 2 Common
N7
NMEA channel 3 A
N8
NMEA channel 3 B
N9
NMEA channel 3 Common
Following sentences are supported.
Date and time
ZDA
Ship’s position and datum used
GNS, DTM, GLL, GGA, RMC, NSR
Speed (water and/or ground)
VBW, VLW, VTG
Heading (true)
THS, HDT
Heading (magnetic)
HDG
Depth (echo sounder)
DPT
CAUTIONs
ALR, ALA, FIR, WAT, ACM
Rudder order/response manual
RSA, ROR
Rudder order/response automatic HTC, HTD
Engine order/response
ETL, PRC, TRC, TRD, RPM, XDR, ROR, RSA
Hull openings, watertight doors
DOR, GEN, XDR
Accelerations and hull stress
HSS, XDR
Wind speed and direction
MWV, MWD
AIS
VDM, VDO, ALR
VDR alert output
ALC, HBT, ALC
Содержание NW6000
Страница 1: ......
Страница 91: ...Page 91 191...
Страница 92: ...Page 92 191...
Страница 116: ...Page 116 191 Figure 16 4 2 Connection figure NMEA Module 16 channels Figure 16 4 3 Connection table NMEA Modules...
Страница 120: ...Page 120 191 Figure 17 4 2 Connection figure Digital Module 16 channels...
Страница 121: ...Page 121 191 Figure 17 4 3 Connection figure Digital Module 24 channels...
Страница 125: ...Page 125 191 Figure 18 4 2 Connection figure Analogue Module 8 channels...
Страница 126: ...Page 126 191 Figure 18 4 3 Connection figure Analogue Module 12 channels...
Страница 184: ...Page 184 191 Figure 5 8 1 Sample dataset playback...