Page 56/ 191
We recommend the above specifications. Alternative cables may be suitable for installations.
Contact us for verification before using cabling other than that specified in the table above.
10.5 Data communications
The unit fully relies on Ethernet connection to the Core module which must be within the VDRs
specified (commissioned) IP-range (refer to 2.5 Network configuration).
10.6 Indicators
Link speed (Green LED):
•
The LED is on when there is a link connection.
•
Otherwise, the LED is off.
Activity (Yellow LED)
•
The LED is flashing when there is activity on the link.
•
Otherwise, the LED is off.
Power supply: red LED.
10.7 Errors
If errors occur within the Core Module these will be indicated on the display of the Bridge Display
Unit.
10.8 PC set-up
To set up the Video Module a service PC should be connected to the module (LAN connection)
and run the VCS2 remotely. To make this connection, complete the steps below:
1.
Connect t
he laptop to the Ethernet port (labeled “Output”) located at the front of the
Video Module.
2.
On the laptop’s desktop screen, open the Control Panel (Start > Control Panel).
3.
Double-
click the ‘Network Connections’ icon, right-click the now visible ‘Local Area
Connection’ icon and select ‘Properties’ from the right-click menu.
4.
Select “Internet Protocol (TCP/IP)” in the connection pane and press the ‘Properties’
button.
5.
Select the ‘Use the following IP address’ radio button, enter 192.168.199.1 in the ‘IP
addres
s’ field and 255.255.255.0 in the ‘Subnet mask’ field. Press ‘OK’.
6.
Select the ‘Advanced’ tab and press the ‘Settings’ button in the ‘Windows Firewall’
section.
7.
Select the ‘Advanced’ tab and press the ‘Settings’ button in the ‘Network Connection
Settings’ section.
Содержание NW6000
Страница 1: ......
Страница 91: ...Page 91 191...
Страница 92: ...Page 92 191...
Страница 116: ...Page 116 191 Figure 16 4 2 Connection figure NMEA Module 16 channels Figure 16 4 3 Connection table NMEA Modules...
Страница 120: ...Page 120 191 Figure 17 4 2 Connection figure Digital Module 16 channels...
Страница 121: ...Page 121 191 Figure 17 4 3 Connection figure Digital Module 24 channels...
Страница 125: ...Page 125 191 Figure 18 4 2 Connection figure Analogue Module 8 channels...
Страница 126: ...Page 126 191 Figure 18 4 3 Connection figure Analogue Module 12 channels...
Страница 184: ...Page 184 191 Figure 5 8 1 Sample dataset playback...