Page 147/ 191
22.5.3 BAM Settings
The VDR can be connected to a Bridge Alert Management (BAM) system if available. When
enabled VDR alert messages will be transmitted to the BAM system. Full details of alert identifiers
are available in the
Figure 22.5.3.1
– Configurator page, BAM settings
BAM Enabled Slider
Used to enable (as shown) or disable BAM.
BAM Interface
Used to enable the ports used for BAM transmission.
Se
lect “
default
” to transmit BAM messages via the ethernet network using LWE.
Select “
Serial
” to transmit alert messages by using an output port on the BCU or Bus
Coupler.