background image

RC-5+ 

PDF Temperature Data Logger

|

|

|

|

Software download: www.elitecheu.com/software

User Manual

Summary of Contents for RC-5+

Page 1: ...RC 5 PDF Temperature Data Logger Software download www elitecheu com software User Manual ...

Page 2: ... for 5 seconds to start recording Ⅰ Press and hold the right key for 5 seconds to stop recording Connect the data logger to a computer to set configuration parameters Quickly click the right key twice to mark the current time and temperature Ⅲ ...

Page 3: ...Default setting Run time 30 days Log interval 2min Trip ID 0000001 Time zone UTC 0 00 Alarm setting no Start mode press button Stop mode press button via software Trip description Temperatrue recording Start delay 0 min Cyclic record disabled Temporary report enable Multi start stop enabled Calibration 0 Timing start mode the data logger starts recording at scheduled time after disconnecting with ...

Page 4: ... 30 C to 70 C Temperature Accuracy Temperature Resolution 0 1 C Data Storage Capacity 32 000 readings Shelf Life Battery 1 years1 CR2032 button cell Recording Interval 2 minutes standard Startup Mode Button or software Stop Mode Button software or stop when full Protection Class IP67 0 5 20 C 40 C 1 0 other range ...

Page 5: ...atic PDF report Password Protection Optional on request Connection Interface USB 2 0 A Type Alarm Configuration Optional up to 5 points Reprogrammable With free Elitech Win or MAC software 1 Depending on optimal storage conditions 15 C to 23 C 45 to 75 rH PDF ElitechLog Win or Mac latest version ...

Page 6: ...roduct Schematic Note Left key function Ⅰ Ⅰ Ⅱ Ⅲ Function Start recording Light the screen turn pages USB protective cover LCD screen Key left Key right Battery cover Operation Press and hold 5s Press once ...

Page 7: ... it Put in a new CR2032 button battery with the negative inward Turn the battery cover clockwise to close it Ⅱ Ⅲ Replace the battery with a coin as follows Operation Press and hold 5s Press once Press twice Function Stop recording Return to main menu Mark the event 6 ...

Page 8: ...ght key in any page to return to the first page 11 12 13 Power indicator Stop status Record status Computer connection Alarm above upper limit Alarm below lower limit Current readings No alarm Marked Date month Maximum temperature Minimum temperature Date day Alarm Mark failed 13 12 11 7 ...

Page 9: ... and transport It can be widely applied to all links of warehousing and cold chain logistics such as refrigerated containers refrigerated trucks cooler boxes cold storage laboratories etc 1 Current temperature 2 Number of readings 5 Maximum temperature 3 Current time hour minute 4 Current date month day 6 Minimum temperature 8 ...

Page 10: ... for the first time The LCD screen will be off after 15 seconds of inactivity Press the left key to lighten it Never dismantle the battery Do not remove it if the logger is running Replace the battery in time for long distance transport if its power remains half Replace old battery with a new CR2032 button cell with the negative inward V3 0 Email service elitech uk com Website www elitecheu com ...