NPU Parameters Summary
WiLink-I Modular Base Station System Manual
187
Downlink QoS Profiles
Up to four QoS Profile Names separated
by commas, where each name (up to 32
printable characters) is a name of a QoS
Profile that exists in the database. The
number of entries in the list must be
identical to number of entries in Downlink
Priority Ranges list.
Yes
Services - QoS Profiles Parameters
QoS Profile Name
Up to 32 printable characters
Yes
QoS Type
2 - RT
3 - NRT
4 - BE
Yes
CT
1 - Short
2 - Medium
3 - Long
Yes
CIR (Kbps)
Applicable to RT and NRT:
0 - 12,000
Yes
MIR (Kbps)
Applicable to NRT and BE:
1 - 12,000. MIR cannot be lower than CIR
(NRT)
Yes
Packet Size (Bytes)
Applicable to CG
64 - 1550 (Bytes)
Yes
Sample Interval (msec)
Applicable to CG
5 - 100 (milliseconds)
Yes
L2 Filtering Rules Parameters
L2 Filtering Rule Name
Up to 32 printable characters
Yes
MAC Address
MAC address or null for Any
Yes
MAC Address Mask
MAC address
Yes
MAC Address Direction
1 - Source
2 - Destination
Yes
Ethertype
4 hexadecimal digits or null for Any
Yes
L3/L4 Filtering Rules Parameters
Table 4-22: NPU Monitor Parameters Summary
Parameter
Range
Default
Run-Time
Updated
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......