32
Installation
Chapter 2 - Installation Guidelines
2.1.6
Connecting the Cables
2.1.6.1
Connecting the Grounding Cable
The Grounding screw (marked
) is located on the bottom panel of the outdoor
unit.
1
Connect one end of a grounding cable to the grounding screw and tighten the
grounding screw firmly.
2
Connect the other end of the grounding cable to a good ground (earth)
connection.
2.1.6.2
Connecting the Antenna Cable
1
Connect one end of the coaxial RF cable to the RF connector (marked )
located on the bottom panel of the unit.
2
Connect the other end of the RF cable to the antenna.
3
The RF connectors should be properly sealed to protect against rain and
moisture.
2.1.6.3
Connecting the IF Cable
1
Connect one end of the coaxial IF cable to the IF connector on the bottom
panel of the unit.
2
Verify that the length of the IF cable is sufficient to reach the AU IDU/Power
Feeder. See IF cable length limitation in
Section 2.1.3
.
3
The IF cable connector should be properly sealed to protect against rain and
moisture.
4
Route the cable to the location selected for the indoor equipment.
To connect the grounding cable:
To connect the RF cable:
To connect the IF cable: