Operation Verification
WiLink-I Modular Base Station System Manual
61
Table 3-5: PIU LEDs
LED Status
Description
PWR
MASTER
Off
Off
Chassis is not connected to power
Red
Off
Power is not connected or power input is out of range or PIU card is
damaged. Chassis is powered by the redundant PIU
Red
Green
Power input is out of range or PIU card damaged. Chassis is powered by
the PIU
Green
Off
Power to PIU is OK. PIU is in redundant mode and the chassis is powered
from the other PIU
Green
Green
Power to PIU is OK. The chassis is powered from the PIU
HOT SWAP
Off: Power from the module to the chassis is not disconnected, the PIU is
not ready for removal
Blue: Power from the module to the chassis can be disconnected and the
PIU can be safely removed
For instructions on using the HOT SWAP handles refer to
Section 2.2.9
.
Table 3-6: PSU LEDs
LED Status
Description
PWR
ALRM
Off
Off
No power or fatal damage
Off
Red
Power input is out of range or PSU is damaged or PSU is inhibited by
NPU
Green
Off
Power is OK and PSU operates properly.
Table 3-7: AVU LEDs
LED Status
Description
PWR
ALRM
Off
Off
No 5V power input
Red
Red
12V power failed
Green
Red
One or more fans have failed
Green
Off
AVU operates properly
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......