Specifications
WiLink-I Modular Base Station System Manual
19
1.5.9
Physical and Electrical
1.5.9.1
Mechanical
* 1U=44.45 mm (1.75"), 1HP=5.08 mm (0.2")
1.5.9.2
Electrical
Table 1-14: Mechanical Specifications, Base Station Equipment
Unit
Dimensions (cm)
Weight (kg)
BST-SH
8U ETSI type shelf, 8U x 43.19 x 24
6.9 (excluding AVU)
PIU
3U x 5HP x 16
0.35
PSU
3U x 8HP x 16
0.7
NPU
6U x 7HP x 16
0.7
AU-IDU
6U x 7HP x 16
0.6
AU-ODU
31.5 x 8.8 x 15.7
2.9
AU-ODU-HP
31.5 x 16 x 16
5.5
AVU
2U x 84HP x 16
1.7
Power Feeder panel
1U ETSI type panel
0.14
Power Feeder Module
15.7 x 14.6 x 3.17
Table 1-15: Electrical Specifications, Base Station Equipment
Unit
Details
Power Source
-40.5 to -60 VDC
Full Base station, including 1 ODU per
AU
640W maximum for a fully equipped base station, including 6 ODUs (1
NPU, 6 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
Full Base station, including 2 regular
ODUs per AU
868W maximum for a fully equipped base station, including 12 regular
ODUs (1 NPU, 6 AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
Full Chassis (excluding ODUs)
412W maximum for a fully equipped chassis, excluding ODUs
(1 NPU, 6 AU-IDUs, 1+1 PIUs, 2+1 PSUs)
Base station with 4 AUs, including 1
regular ODU per AU
470W maximum for a chassis with 4 AUs, including 4 regular ODUs (1
NPU, 4 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
Base station with 4 AUs, including 2
regular ODUs per AU
621W maximum for a chassis with 4 AUs, including 8 ODUs (1 NPU, 4
AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
Chassis with 4 AUs (excluding ODUs)
317W maximum for a chassis with 4 AUs, excluding ODUs (1 NPU, 4
AU-IDUs, 1+1 PIUs, 2+1 PSUs)
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......