Operation Verification
WiLink-I Modular Base Station System Manual
59
3.2.2
Base Station LEDs
To verify the correct operation of the Base Station equipment, examine the LED
indicators located on the front panels of the modules. The following tables list the
LEDs of the Base Station modules and their associated indications.
Table 3-3: AU-IDU LEDs
Name
Description
Functionality
PWR
Power indication
¢
Off - AU-IDU is not powered
¢
Red - AU-IDU power supply failed (low power)
¢
Green - AU-IDU power is OK
ALARM
Alarm indication
¢
Off - AU-IDU is OK
¢
Red - AU-IDU failure
WLINK
Wireless link status indication
¢
Off - No SU is associated
¢
Green - At least one SU is associated
WACT
IDU transmission indication
¢
Off - No IDU transmission
¢
Green - IDU transmission OK
SP
Spare
Not Used
IP
IP activity indication
¢
Off - No downlink (AU to SU) IP activity
¢
Green (blinking) - Downlink (AU to SU) IP activity
ODU1/ODU2 PWR
IDU to ODU Power Indication
¢
Off - No IDU to ODU power output
¢
Red - IDU to ODU power output failed
¢
Green - IDU to ODU power output OK
ODU1/ODU2 ALRM
IDU-ODU communication
status
¢
Off - IDU-ODU communication OK
¢
Red - IDU-ODU communication failure
HOT SWAP
IDU readiness for hot swap
removal
¢
Off: Power to the module is not disconnected, the
AU-IDU is not ready for removal
¢
Blue: Power to the module can be disconnected
and the AU-IDU can be safely removed
For instructions on using the HOT SWAP handles refer
to
Section 2.2.9
.
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......