Configuring Basic Parameters of Base Station
WiLink-I Modular Base Station System Manual
57
¢
All parameters of both ports should be configured. Otherwise, default values
shall be used.
¢
If OOB management via a router connected to the Management port is used,
the parameters should be configured to ensure different subnets for the Data
port, the Management port (local OOB management) and the Management Port
Destination. The Management Port Destination Subnet is the subnet behind a
router connected to the Management port.
¢
Authorized Manager(s) must be configured properly to enable remote
management using bwaNMS (or another SNMP based application).
Once the basic parameters have been configured, additional parameters and
services can be remotely configured using either SNMP management or the
Monitor application via Telnet. Alternatively, it is possible to continue the
configuration process using the Monitor application via the MON serial port.
Refer to Chapter 4 - Operation and Administration for information on how to
access the Monitor application either via the MON port or via Telnet and how to
use it.
NOTE
It is highly recommended to use the Management port for local management only. Typically the port
should be down (disconnected).
CAUTION
Do not configure the IP Address of the Management port to 0.0.0.0, as this will cause loss of
management connectivity via the DATA port.
NOTE
If no Authorized Manager is defined in the device, it can be managed using SNMP by any station. If
at least one Authorized Manager is defined, the device can be managed only by a station whose
parameters match a defined Authorized Manager.
NOTE
The default Installer password is "installer".
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......