18
System Description
Chapter 1 - System Description
1.5.8
Services
Table 1-13: Services
Item
Description
Max number of Services per
BST
4,095 (0ne or several services may be defined per subscriber, one or more
subscribers can be supported per SU)
Min number of data
connections per Service
2 (1 uplink, 1 downlink)
Max number of data
connections per Service
8 (4 uplink, 4 downlink)
Max number of data
connections per SU
126
Max number of data
connections per AU
3999 - 3 x number of SUs (3 connections are reserved for each SU)
Max number of SUs per AU
510
Max number of AUs per BST
7
Max number of MAC addresses
in Bridging Table
BST: 6,000
SU: 512
(Aging time is configurable. The default is 3 minutes for SU, 10 minutes for NPU)
Max number of VLANs per
Service
16
Max number of VLANs per SU
16
Max number of VLANs
(VPL IDs) per BST
1,024
Max number of concurrent
voice calls per Voice/L2
Service
50
Max number of concurrent
voice calls per AU
300
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......