Installing the Base Station Equipment
WiLink-I Modular Base Station System Manual
45
1
Firmly push in the module into its intended slot.
2
Press the handle down until you hear the locking click and the red button is
released.
3
Secure the module in place by closing the screw at the top of the front panel.
2.2.9.2
Ejecting Modules
1
Release the screws at the top and the bottom of the front panel.
2
Press the handles' red button until the handles are unlocked.
3
Wait until the blue HOT SWAP LED turns on, indicationg that the module has
been disconnected and can be removed.
4
Press the handles down (the upper handle)/up (the lower handle) until the
module is unlocked, firmly hold the handles and take the module out of the
chassis.
NOTE
If a module is fully inserted without properly locking the handles, it will become operational.
However, in this state the hot-swap mechanism is not supported. A warning message (trap) will be
sent.
To insert a PSU or a PIU without HOT SWAP support:
CAUTION
In a PIU without HOT SWAP LED, disconnect power from the PIU module before inserting it to the
chassis.
To eject a module with hot-swap support (NPU, AU-IDU, new PIU):
CAUTION
In a PIU with HOT SWAP LED, disconnect power from the PIU module only after it is taken out from
the chassis (or after the HOT SWAP LED is turned on).
Содержание WiLink-I 3000
Страница 1: ...System Manual WiLink I Modular Base Station SW Version 2 5 June 2006 ...
Страница 16: ......
Страница 20: ......
Страница 24: ...4 System Description Chapter 1 System Description Figure 1 1 WiLink I System Architecture ...
Страница 42: ......
Страница 74: ......
Страница 214: ......
Страница 240: ......