Loss of Communication With Partition Remote console interface
3-3
See the
Hardware Installation Guide
or
Service Guide
for cabling details.
6. If you are using a network hub for the network connections surrounding your system,
reset or reboot the network hub to attempt to clear any possible network problems.
If none of the previous steps resolve your communication problem with your Service
Processor, continue with
3.2.3 Verifying Partition Network Settings
3.2.3.
Verifying Partition Network Settings
1. Using the EXPRESSSCOPE® Monitor interface on the individual cells in your
system, locate your boot cell.
Figure 3-2 Location of Boot Cell Indicator on Main Screen of EXPRESSSCOPE® Monitor
Interface
2. On the main menu of the EXPRESSSCOPE® Monitor LCD on your boot cell, use
the navigation buttons to select
Partition
, and then press
OK
.
3. On the partition menu, use the navigation buttons to select
Network
, and then
4. press
OK
.
5. Verify that the IP address displayed for the partition is the one you are using to
remotely access the partition.
y
If the IP address is correct, skip to
3.2.4 Rebooting the Service Processor
.
y
If the IP address is 0.0.0.0 and DHCP is enabled
-
Ensure that a Dynamic Host Configuration Protocol (DHCP) server is
accessible, and wait for an address to free up or contact your network
administrator to request addresses. (The DHCP server may have
temporarily run out of addresses for the network segment your system is
on and is waiting to reclaim unused addresses, or, if your system was
repartitioned recently, the partition may be still acquiring an address.)
-
If no DHCP server is accessible, disable DHCP addressing and use static
addressing instead.