Error Messages Displayed on EXPRESSSCOPE® Monitor LCD
3-10
y
Ensure that a DHCP server is accessible, and wait for an address to free up or
contact your network administrator to request addresses. (The DHCP server
may have temporarily run out of addresses for the network segment your
system is on and is waiting to reclaim unused addresses, or, if your system
was repartitioned recently, it may be still acquiring an address.)
y
If no DHCP server is accessible, disable DHCP addressing and use static
addressing instead. If the IP address is 0.0.0.0 and DHCP is disabled,
y
Locate the static IP address that was assigned to the partition (see initial
installation documentation) and set it. (Refer to
5.3.1 Configuring Network
Settings
or the
User’s Guide
.) Then use the EXPRESSSCOPE® Monitor LCD
to verify that the partition successfully obtained the address.
y
If the IP address remains as 0.0.0.0, check the main menu of the
EXPRESSSCOPE® Monitor LCD for other error messages.
3.4.5.
Message: “Switch Error”
This message indicates that the Ethernet switch on the Service Processor was not able
to initialize correctly.
Solution
: Reboot your Service Processor.
Locate the management board reset button on the rear of the cell and press it with a slim
blunt-tip tool (for example, the tip of a pen).
Figure 3-5 Location of Management Board Reset Button
After pressing the management board reset button on the cell, both green and amber
LEDs left of the reset button blink quickly. Then, after about 10 seconds, the green LED
blinks slowly, indicating that the Service Processor is rebooted. Normal operations can
resume when you can access the partition remote console interface, usually after
another 30 seconds.