Error Messages Displayed on EXPRESSSCOPE® Monitor LCD
3-6
LEDs left of the reset button blink quickly. Then, after about 10 seconds, the green LED
blinks slowly, indicating that the Service Processor is rebooted. Normal operations can
resume when you can access the partition remote console interface, usually after
another 30 seconds.
If there are still problems when the Service Processor is rebooted, continue with the
following troubleshooting procedures.
3.3.2.
Checking Cell Interconnect Cable Connections
Check the following:
y
All cell interconnect cables for your system are present and correctly cabled (see
the
Hardware Installation Guide
or
Service Guide
for cabling details).
y
The A and B connectors are not reversed.
y
All cables are securely seated and thumbscrews are snug.
3.3.3.
Restoring the Service Processor to Default Settings
Restoring the Service Processor to default settings is a drastic measure that requires
configuring most of the settings on the Service Processor, possibly including settings
configured in the factory or before or during installation.
The partition must be DC powered down before you restore the associated Service
Processors to default settings. Only restore one Service Processor at a time; do not
restore multiple Service Processors simultaneously.
To restore your Service Processor to default settings, see
Section 4 Restoring the
Service Processor
.
After restoring your Service Processor, see
5.2 Configuring After Restoring Default
Settings
for reconfiguration procedures.
If there are still problems when you have restored and reconfigured your Service
Processor, return to the beginning of this section to continue troubleshooting.
Alternatively, you can contact your service representative for resolving problems.
3.4. Error Messages Displayed on EXPRESSSCOPE®
Monitor LCD
This section lists error messages displayed (enclosed in quotation marks) on the
EXPRESSSCOPE® Monitor interface on the cell, and troubleshooting tips for resolving
each error.