![NEC NECCare Platinum Express5800/A1160 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/nec/neccare-platinum-express5800-a1160/neccare-platinum-express5800-a1160_troubleshooting-manual_4276039023.webp)
Cell Is Not Responding
3-5
configuring most of the settings on the Service Processor, possibly including settings
configured in the factory or before or during installation.
The partition must be DC powered down before you restore the associated Service
Processors to default settings. Only restore one Service Processor at a time; do not
restore multiple Service Processors simultaneously.
To restore your Service Processor to default settings, see
Section 4 Restoring the
Service Processor
.
After restoring your Service Processor, see
5.2 Configuring After Restoring Default
Settings
for reconfiguration procedures.
If there are still problems when you have restored and reconfigured your Service
Processor, return to the beginning of this section to continue troubleshooting.
Alternatively, you can contact your service representative for resolving problems.
3.3. Cell Is Not Responding
Perform the following troubleshooting steps when
y
The partition summary page of the remote console interface reports an unknown
state for one or more cells.
y
The EXPRESSSCOPE® Monitor interface on the cell displays a truncated and
sparse menu.
3.3.1.
Rebooting the Service Processor
To reboot your Service Processor, locate the management board reset button on the
rear of the cell and press it with a slim blunt-tip tool (for example, the tip of a pen).
Figure 3-4 Location of Management Board Reset Button
After pressing the management board reset button on the cell, both green and amber