background image

PxV206 – 2U Platform

User’s Manual

Version 1.01

Kontron Embedded Computers GmbH

0-0096-2594

Summary of Contents for PxV206

Page 1: ...PxV206 2U Platform User s Manual Version 1 01 Kontron Embedded Computers GmbH 0 0096 2594 ...

Page 2: ...e Lithium Battery 9 FCC Statement 10 Electromagnetic Compatibility 10 Scope of Delivery 11 Type Labels and Product Identification 11 Product Description 12 Front Panel 14 Drive Door 15 Serial Interface Connector COM1 15 Combined PS 2 Mouse and Keyboard Connector 15 Operating Elements 16 Fan Door 16 Front Panel LEDs Status 17 Rear Panel 18 Ports on the Rear Side 19 Power Supply Unit 19 Versions of ...

Page 3: ... Installation in a 19 Cabinet 32 Maintenance and Prevention 34 Changing the Air Filter Mat 34 Lithium Battery 35 Main Specifications 36 Electrical Specifications 38 Mechanical Specifications 38 Environmental Specifications 39 CE Directives Standards and Approvals 40 Technical Appendix Interfaces 41 RS232 41 RS422 COM 2 only RS485 COM2 only 42 PS 2 Keyboard and Mouse Connector 42 Parallel Port 43 T...

Page 4: ... for this reason Kontron Embedded Computers expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every individual case In cases of doubt please contact Kontron Embedded Computers This manual is protected by copyright All rights are reserved by Kontron Embedded Computers Copies of all or part of this m...

Page 5: ...the risk of damage to the product if the corresponding warning notices are not observed This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed This symbol indicates general information about the product and the user manual This symbol precedes helpful hints and tips for daily use ...

Page 6: ...that provided by law This applies for example batteries Exclusion of Accident Liability Obligation Kontron Embedded Computers shall be exempted from the statutory accident liability obligation if the user fails to observe the safety instructions Liability Limitation Exemption from the Guarantee Obligation In the event of damage to the device caused by failure to observe the hints in this manual an...

Page 7: ...ctions for use q The electrical installations in the room must correspond to the requirements of the respective regulations q Take care that there are no cables particularly mains cables in areas where persons can trip over them q Do not use a mains connection in sockets shared by a number of other power consumers Do not use an extension cable q Only use the mains cable supplied q The unit is comp...

Page 8: ...ers q Maintenance or repair on the open device may only be carried out by qualified personnel authorised by Kontron Embedded Computers familiar with the associated dangers q The device may only be opened for the installation and removal of extension cards in accordance with the description in this manual q If extensions are made to the device the legal stipulations and the device specifications mu...

Page 9: ...1040 for the USA and Canadian Radiation Emitting Devices Act REDR C 1370 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry Proper packaging and grounding techniques are necessary precautions to prevent damage Always take the following precautions 1 Transport boards in static safe containers such as boxes or bags 2 Ke...

Page 10: ...ins leads or circuitry 5 Turn off power and input signals before inserting and removing connectors or test equipment 6 Keep work area free of non conductive materials such as ordinary plastic assembly aids and Styrofoam 7 Use field service tools such as cutters screwdrivers and vacuums that are conductive 8 Always place drives and boards PCB assembly side down on the foam Instructions for the Lith...

Page 11: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in residential area is likely to cause harmful interference in witch case the user will be required to correct the interference at his own expense Electromagnetic Compatibility This product has been designed for industrial commercial and office use including small business use The most re...

Page 12: ...or AC power supply units q Rubber feet and screws q Y adapter cable PS 2 Keyboard Mouse Type Labels and Product Identification The type label of your PxV206 2U Platform is attached to the inside of the drive door Type label Product identification PxV206 A PxV206 2U Platform with AC power supply unit PxV206 B PxV206 2U Platform with AC power supply unit PxV206 C PxV206 2U Platform with DC power sup...

Page 13: ...disk IDE The hard disk is located on the bottom of the unit between the power supply unit and floppy drive The unit incorporates E PAC technology to simplify the installation and the removal of its components HDD FDD or CD ROM drive The front side cooling fans are mounted into E PAC This advanced technology is also extreme resistant to shock and vibrations and a definite air stream for the system ...

Page 14: ...ser s Manual 13 1 10 2 9 8 11 7 6 4 5 3 Fig 3 PxV206 2U Platform opened 1 Power Supply Unit PSU 2 Floppy drive 3 5 3 CD ROM drive 5 25 4 Backplane 5 SBC board 6 E PAC 7 Front cooling fans 8 Air filter mat 9 LED panel 10 Drive door 11 Fan door ...

Page 15: ...ith closed doors 1 3 2 Fig 4a Front panel desktop version with closed doors 6 8 7 9 10 11 Fig 4b Front panel rackmout and desktop version with opened doors 1 Drives door with lock 2 Panel section with LEDs 3 Fan door with knurled screw 4 Holes for in rack mount 5 Handles 6 CD ROM and Floppy drive 7 Reset button 8 Power switch 9 Serial port COM1 RS 232 10 PS 2 Keyboard Mouse connector 11 Front cool...

Page 16: ...rson The PxV206 2U Platform comes equipped with one key If the key get lost or damaged then the drive door can only be opened by Kontron service personnel Serial Interface Connector COM1 This connector labelled COM1 see fig 4b pos 9 is available as a 9 pin D SUB plug and allows you to connect serial peripheral The interface is configured as RS232 Combined PS 2 Mouse and Keyboard Connector To this ...

Page 17: ...ain power source by turning off the Power Switch The unit is completely disconnected from the main power source only q when the power cord is disconnected either from the power source or the unit Or for systems with redundant PSU q by turning off the power on off switch of the AC redundant PSU Therefore the power cord and its connectors must always remain easily accessible Reset Button If your sys...

Page 18: ...T AC ON Operating system is OK ON OFF Not working system 1 System power LED green OFF System power LED green blinking The system is operating some failure occurred on the redundant PSU 2 HDD Activity LED orange HDD Activity LED orange 3 Not used Not used 4 Not used Not used 5 Not used Not used 6 Not used Not used 7 Not used Not used 1 System Power LED 2 HDD LED ...

Page 19: ...it 1 2 3 4 5 6 7 8 9 Fig 6 Rear panel with AC PSU 1 2 3 4 5 6 7 8 9 Fig 6a Rear panel with DC PSU 1 3 4 5 6 7 9 8 2 Fig 6b Rear panel with AC redundant PSU 1 Serial port COM2 2 Parallel port LPT 3 5x free slots 4x PCI and 1x ISA 4 1x SBC board 5 Ground stud 6 Fan of the power supply unit 7 AC or DC Power inlet of the power supply unit according to the used PSU 8 Cover captive knurled screw 9 Card ...

Page 20: ...l port Nonetheless depending on the device the manufacturers instructions must be observed and the necessary software driver installed Serial Interface Connector COM2 This connection labelled COM2 is available as a 9 pin D SUB plug and allows you to connect serial peripheral The interface can be configured as RS232 RS422 or RS485 SBC Board External Interfaces The SBC board external interfaces may ...

Page 21: ...m refer to the type label attached at the inside of the drive door System Version Integrated PSU Input PxV206 A AC PSU 100 240 VAC 50 60 Hz max 320 W PxV206 B AC PSU 100 240 VAC 50 60 Hz max 300 W PxV206 C DC PSU 50 to 60 VDC max 250 W PxV206 D AC redundant PSU 115 230 VAC 50 60 Hz max 320 W For PxV206 C only it is not allowed to remove or to bridge the ATX plug with the Kontron ATX extension a T1...

Page 22: ... button and it is equipped with acoustical and display controls 1 2 3 4 5 5 6 6 7 8 7 8 Fig 7 AC redundant PSU 1 Power plug 2 PSU Power switch 3 PSU Alarm reset button 4 Redundant PSU LED 5 Screws for removing installing the redundant PSUs 6 Handle 7 AC Power status LED 8 DC Power status LED During operation all LED control displays of the redundant power supply unit are on ...

Page 23: ...ive PSU On blink On blink On On On Off The system is operating with one defective PSU If a failure occurred and one of the PSU modules is defective the redundant PSU LED start to blink and a beep is audible The DC Power status LED from the defective redundant PSU module is not on The PxV206 2U Platform is continuing to operate with one of the power supply modules By press of the PSU alarm reset bu...

Page 24: ...unit to have access to the back side of the PxV206 2U Platform loosen the 4 screws for in rack mounting 3 Locate the defective power supply module by examining the status of DC power status LEDs of the redundant PSU 4 Unscrew and remove the defective PSU module 5 Replace by inserting the new a good one PSU module into the PSU chassis and screw it on 6 Check the DC OK LED which indicate the power s...

Page 25: ...ovided for the standard version with q two PICMG SBC locations only one SBC installed at any given time q four PCI expansion slots to expand your system three of them full size and one of them half size q one ISA expansion slot half size to expand your system 3 4 Fig 8 Backplane front side 1 2 4 5 Fig 8a Backplane rear side 1 Power connector for front fans 2 Connector for main power switch 3 Power...

Page 26: ...e chapter Main Specifications and that every additional card does not exceed 25 W power consumption SBC Board The standard unit is equipped with one 32 bit SBC board Your system can accommodate a Pentium III Celeron or a Pentium 4 Celeron CPU compatible Single Board Computer SBC For detailed information refer to the delivered technical reference manual of the SBC board ...

Page 27: ...ow these steps to install the rubber feet Fig 9 Screw inside a rubber foot 1 First make sure that all boards are secured in the unit and that the cover of the system is installed and secured 2 Turn the system upside down 3 Position the four rubber feet at each corner of the system 4 Insert one screw inside each rubber foot and secure them to the system ...

Page 28: ...nce with the description in this manual Before removing the cover to gain access to the internal components the system must be powered down and the power cord has to be disconnected from the power source To expand your system with additional cards please observe the power consumption specification specified in the chapter Main Specifications and that every additional card does not exceed 25 W powe...

Page 29: ...n additional card complete the following steps 1 Turn off all power sources 2 Remove the captive knurled screw located at the rear of the unit securing the cover Fig 10 Removing cover 3 Lift the back of the cover and pull it out Fig 11 Removing cover Fig 12 PxV206 2U without cover ...

Page 30: ...ew on the bottom part of the rear panel Fig 13 Removing the captive knurled screw 5 Disconnect all data and power cables from the SBC card 6 Pull out and lift the card cage from the housing Fig 14 Removing card cage with SBC board 7 Remove install the additional card from to the backplane slots ...

Page 31: ...et AC Connection with redundant PSU SRZ HU LQOHW AC power plug Fig 16 AC redundant power connection 1 Connect the AC power cord into the system AC power plug 2 Connect the AC power cord into a outlet 3 Set the power supply switch to On Do not remove or alter the grounding prong on the power cord In situations where a two slot receptacle is present have it replaced with a properly grounded three pr...

Page 32: ...system If you ordered your system with installed operating system all drivers are installed corresponding to the ordered system configuration optional hardware components Your PxV206 is fully functional when you switch it on for the first time If you ordered your system without installed operating system you have to install the operating system and the corresponding drivers for the ordered system ...

Page 33: ...ith redundant power supply unit in a rack the PSU power switch must be set to I see also chapter Redundant Power Supply Unit Important Instructions Make sure there is sufficient air circulation around the device when installing the PxV206 2U The openings for air intake and exhaust on the device and the 19 industrial cabinet must not be obstructed When installing the 2U Platform in a 19 cabinet lea...

Page 34: ...verloaded Adjust the cabling and the external overcharge protection to correspond with the electrical values indicated on the type label The type label is located on the inside of the drive door For DC power supplies please observe that the supply circuit must withstand loads minimum 25A for the 48V power supply ...

Page 35: ...ly remove persistent dirt by use of a soft slightly damp cloth use only a mild detergent q Clean regularly the air filter mats Changing the Air Filter Mat Cleaning frequency will depend on the operating environment If the environment is extremely dusty clean the air filter mat more often The air filter mat can be changed even if the system is powered up 2 3 1 Fig 18 Dust filter placing 1 Fan door ...

Page 36: ...o possible to beat it out vacuum it or blast it with warm compressed air q If the filter is soiled with greasy dust you should rinse it with warm water with degreaser added Do not clean the filter mat with a piercing jet of water or wring it out 4 After cleaning and drying of the air filter mat put these over the fans close the fan door and tighten the captive knurled screw Lithium Battery The SBC...

Page 37: ...arallel port LPT SPP ECP EPP 1x serial port COM2 configurable as RS232 RS422 RS485 On the front side panel 1x serial port COM1 configured as RS232 1x combined PS 2 Keyboard Mouse connector Slots On the rear panel 1x 32 bit PICMG slot for the SBC card 1x PCI half size 3x PCI full size 1x ISA half size Operating elements On the front panel Power switch Reset button On rear panel only units with AC r...

Page 38: ...al power of all additional customized applications for PxV206 C PxV206 D 95 W Power of each used interface ISA resp PCI 25 W Power on 12 VDC 30 W Power on 12 VDC 8 W Power on 5 VDC 1 W Power on 5 VDC 80 W Power on 3 3 VDC 30 W Power specification max power value for additional customized applications Power on 5 VSB 1 W Please take care that the total PSU output power of your system doesn t exceed ...

Page 39: ...Hz max 320 W PxV206 B AC PSU 100 240 VAC 50 60 Hz max 300 W PxV206 C DC PSU 50 to 60 VDC max 250 W PxV206 D AC redundant PSU 115 230 VAC 50 60 Hz max 320 W Mechanical Specifications Dimensions Height 2U x 19 88 9 mm Width 16 90 430 2 mm Depth 18 457 2 mm Weight 10 kg approximately without packaging Housing steel with zinc plating ALU front panel black ...

Page 40: ... F Storage transit temperature humidity 40 70 C 5 95 40 C 40 158 F 5 95 104 F Operating altitude 10 000 ft 3 048 m Storage transit altitude 50 000 ft 15 240 m Operating shock 15 G max at 11 ms duration half sinus 6 axis Storage transit shock 30 G max at 11 ms duration half sinus 6 axis Operating vibration 10 58 Hz 0 075 mm 58 500 Hz 1 0 G Storage transit vibration 10 58 Hz 0 15 mm 58 500 Hz 2 0 G ...

Page 41: ...cal Safety 73 23 EEC EMC Directive 89 336 EEC Electrical Safety Standards EUROPE EN 60950 3 rd edition EMC Standards EUROPE EN 50081 1 2 emission EN 50082 1 EN 61000 6 2 immunity EN 55022 B 1998 CISPR22 U S A FCC 47 CFR Ch1 2 902 Verification Procedure Agency Approvals Standards Designed to meet TÜV EN 60950 Designed to meet UL UL 60950 ...

Page 42: ...gnments for the external connections of the PxV206 2U Platform Low active are indicated by a minus sign RS232 Pin Signal name 9 pin SUB D plug 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear to Send 9 RI Ring Indicator ...

Page 43: ...d 5 GND Signal Ground 6 not connected 7 RX Receive Data 8 TX Transmit Data 9 not connected 1 not connected 2 RX TX Receive Transmit 3 not connected 4 not connected 5 GND Signal Ground 6 not connected 7 RX TX Receive Transmit 8 not connected 9 not connected PS 2 Keyboard and Mouse Connector Pin Signal name 6 pin Mini DIN socket 1 Keyboard data 2 Mouse data 3 GND 4 5 V 5 Keyboard clock 6 Mouse clock...

Page 44: ...206 2U Platform User s Manual 43 Parallel Port Pin Signal name 25 pin SUB D socket 1 STROBE 2 DATA0 3 DATA1 4 DATA2 5 DATA3 6 DATA4 7 DATA5 8 DATA6 9 DATA7 10 ACKN 11 BUSY 12 PE 13 SELECT 14 AUTOFD 15 ERROR 16 INIT 17 SLCTIN 18 25 GND ...

Page 45: ... call the unit part number P No and the serial number S No of the defective unit provide the serial number found on the type label inside of the drives door Be ready to explain the nature of your problem to the service technician If you have any questions about Kontron Embedded Computers or our products and services you may reach us at the aforementioned numbers or at www kontron com or by writing...

Page 46: ...umber from Kontron Embedded Computers Service before returning any merchandise Clearly write or mark this number on the outside of the package you are returning 3 Describe the device failure behavior 4 Include the name and telephone number of a person whom we can contact for further explanations if necessary when returning goods Where applicable always include all duty papers and invoice s associa...