CHAPTER 7
NDA-24299
Page 160
Revision 1.0
TROUBLESHOOTING
3-B PM C-level Infinite Loop (Permanent)
shows a sample system configuration. The number of cards and cables may vary depending on the
system.
Figure 7-1 Related Hardware
2. 3-B PM C-level Infinite Loop (Permanent)
This message is displayed when a C-level program abnormal state has been detected as permanent. When
the abnormal state is detected by the Port Microprocessor (PM) on an FCH card, the PM places the card
into make-busy status. If the failure occurs more than 15 times an hour, the system judges the failure as
permanent, issuing 3-B system message. Refer to
Figure 7-2 3-B PM C-level Infinite Loop (Permanent)
: 1 0 B A S E -T c a b le
: F ro n t C a b le
06
04 05
03
02
01
00
06
04 05
03
02
01
00
CN
CN
CN
CN
CN
CN
BASEU
PIM 1
PIM 0
LPM
TOPU
BSC M
CN
CN
CN
FC H
D TI
H U B
F C H
D TI
1 3 -H
"S ig n a lin g L in k F a ilu re "
1 . 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0
2 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
M A T
F R O N T V IE W
S y ste m M e ssa ge
1. xx00 0000 0000 0000 2. 0000 0000 0000 0000.........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group (0/1)
U: Unit (0-3)
G: Group (00-23)
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...