Connecting Cables
4.2 Connecting 10 BASE-T Cables
shows sample cable connections, where HUB (PA-M96) cards are provided in a dual
configuration and the FCH (PA-FCHA) card is located in PIM 1 (1-IMG system/IMG0). When HUB cards
are provided in a dual configuration, the two HUB cards must be connected on each front edge connector
with a 10 BASE-T cross cable. However, when dual LANIs (LANI-A and LANI-B) are used for each CPU,
the cross cable connection between HUBs for FCH#0 and #1 is not necessary.
Note:
The Ethernet cables shown in the examples in this section are NOT available from NEC. The customer must
provide these cables, depending on the system configuration. See “
Chapter 6 Connecting 10 BASE-T
.”
Figure 4-11 Overall 10 BASE-T Connections
Note:
When connecting the MAT using a HUB card, be sure to use a dedicated HUB for the MAT.
A T T E N T IO N
C on te n ts
S ta tic S e ns itiv e
H an d ling
P re ca u tion s R e q uire d
DTI (PA-24DTR)
DTI
LANI (PZ-PC19)
LANI (PZ-PC19)
10 BASE T cable
(straight)
10 BASE T cable
(straight)
: 10 BASE-T cable (for Fusion Link)
: 10 BASE-T cable (for MAT)
MAT
P
IM
1
P
IM
0
H
U
B
(P
A
-M
96
)
H
U
B
(P
A
-M
96
)
H
U
B
(P
A
-M
96
)
G T
G T
to MAT
REAR VIEW
Note
10 BASE T cable
(cross)
FCH (PA-FCHA)
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...