NDA-24299
CHAPTER 5
Page 101
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
The example data setting is shown using
, on condition that CCIS link data has already been
assigned between FPC2 (PC2) and PC3 nodes.
Figure 5-44 FCCS - CCIS Coexisting Network
The following data setting must be assigned at FPC1 (PC1) node in the example.
STEP 1:
ASYD
Assign the OPC (Originating Point Code) within the range 1-16383.
Index 180, 181:
Ex.) OPC=16
Miscellaneous Data
Index 186:
b6 must be assigned as “1 (CCIS is in service).” The remaining data should be determined depending
on the customer’s requirements.
STEP 2:
ANPDL/ANPDN
Assign the first digit and NND (Number of Necessary digit) of the LCR access code.
1st DC=7
CI=N (Normal)/H (Hooking)NND=2
STEP 3:
ASPAL/ASPAN
Assign the dummy route number to the LCR access code.
ACC=75
SRV=LCRLGRT=Dummy route number
FC
CS
FCCS: Fusion Call Control Signal
C
C
IS
FPC 1
LN
Office Identification Code=75
LGRT=1
CCH=00020
ACC=75
STN: 2000
FPC 2
PC 3
PC 2
PC 1
CCIS: Common Cannel Interoffice Signal
NCN
ffice Identification Code=76
0 0 0 0 0 0
0 0
0 0 0 0
1
0
b5
b0
b7
b0
Index 181
Index 180
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...